-- extracted from draft-ietf-disman-remops-mib-07.txt -- at Mon Nov 15 17:11:23 1999 DISMAN-PING-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, experimental, Counter32, Unsigned32, NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI -- RFC2578 TEXTUAL-CONVENTION, RowStatus, StorageType, DateAndTime, TruthValue FROM SNMPv2-TC -- RFC2579 MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF -- RFC2580 InterfaceIndexOrZero -- RFC2233 FROM IF-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB; -- RFC2571 pingMIB MODULE-IDENTITY LAST-UPDATED "9908280000Z" ORGANIZATION "IETF Distributed Management Working Group" CONTACT-INFO "Kenneth White International Business Machines Corporation Network Computing Software Division Research Triangle Park, NC, USA E-mail: wkenneth@us.ibm.com" DESCRIPTION "The Ping MIB (DISMAN-PING-MIB) provides the capability of controlling the use of the ping function at a remote host." -- Note: This OID should be reassigned by IANA when the internet-draft -- containing this MIB module is issued as an RFC. ::= { experimental 84 1 } -- Textual Conventions HostAddressType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The textual convention for defining the type of a destination address." SYNTAX INTEGER { none(0), dnsName(1), -- Utf8string encoded DNS name ipv4(2), -- ipv4 address ipv6(3) -- ipv6 address } HostAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The textual convention for specifying a host address. The type of address can be determined by examining the value of the preceding HostAddressType object: HostAddressType OCTETs ADDRESS TYPE none(0) 0 not specified dnsName(1) 1-255 DNS name ipv4(2) 4 ipv4 ipv6(3) 16 ipv6" SYNTAX OCTET STRING (SIZE (0..255)) IpHostAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The textual convention for specifying an IP host address. The type of address can be determined by the octet string length: OCTETs ADDRESS TYPE 0 not specified 4 ipv4 16 ipv6" SYNTAX OCTET STRING (SIZE (0..16)) OperationResponseStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Used to report the result of an operation: responseReceived(1) - Operation completes successfully. unknown(2) - Operation failed due to unknown error. internalError(3) - An implementation detected an error in its own processing that caused an operation to fail. requestTimedOut(4) - Operation failed to receive a valid reply within the time limit imposed on it. unknownDestinationAddress(5) - Invalid destination address. noRouteToTarget(6) - Could not find a route to target. interfaceInactiveToTarget(7) - The interface to be used in sending a probe is inactive without an alternate route existing. arpFailure(8) - Unable to resolve a target address to a media specific address. maxConcurrentLimitReached(9) - The maximum number of concurrent active operations would have been exceeded if the corresponding operation was allowed. unableToResolveDnsName(10) - The DNS name specified was unable to be mapped to an IP address. invalidHostAddress(11) - The IP address for a host has been determined to be invalid. Examples of this are broadcast or multicast addresses." SYNTAX INTEGER { responseReceived(1), unknown(2), internalError(3), requestTimedOut(4), unknownDestinationAddress(5), noRouteToTarget(6), interfaceInactiveToTarget(7), arpFailure(8), maxConcurrentLimitReached(9), unableToResolveDnsName(10), invalidHostAddress(11) } -- Top level structure of the MIB pingNotifications OBJECT IDENTIFIER ::= { pingMIB 0 } pingObjects OBJECT IDENTIFIER ::= { pingMIB 1 } pingConformance OBJECT IDENTIFIER ::= { pingMIB 2 } -- The registration node (point) for ping implementation types pingImplementationTypeDomains OBJECT IDENTIFIER ::= { pingMIB 3 } pingIcmpEcho OBJECT-IDENTITY STATUS current DESCRIPTION "Indicates that an implementation is using the InterNet Control Message Protocol (ICMP) 'ECHO' facility." ::= { pingImplementationTypeDomains 1 } pingUdpEcho OBJECT-IDENTITY STATUS current DESCRIPTION "Indicates that an implementation is using the udp echo port (7)." REFERENCE "RFC 862, 'Echo Protocol'." ::= { pingImplementationTypeDomains 2 } pingSnmpQuery OBJECT-IDENTITY STATUS current DESCRIPTION "Indicates that an implementation is an SNMP query to calculate a round trip time." ::= { pingImplementationTypeDomains 3 } pingTcpConnectionAttempt OBJECT-IDENTITY STATUS current DESCRIPTION "Indicates that an implementation is attempting to connect to a TCP port in order to calculate a round trip time." ::= { pingImplementationTypeDomains 4 } -- Simple Object Definitions pingMaxConcurrentRequests OBJECT-TYPE SYNTAX Unsigned32 UNITS "requests" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of concurrent active ping requests that are allowed within an agent implementation. A value of 0 for this object implies that there is no limit for the number of concurrent active requests in effect." DEFVAL { 10 } ::= { pingObjects 1 } -- Ping Control Table pingCtlTable OBJECT-TYPE SYNTAX SEQUENCE OF PingCtlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the ping Control Table for providing, via SNMP, the capability of performing ping operations at a remote host. The results of these operations are stored in the pingResultsTable and the pingProbeHistoryTable." ::= { pingObjects 2 } pingCtlEntry OBJECT-TYPE SYNTAX PingCtlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the pingCtlTable. The 1st index element, pingCtlOwnerIndex, is of the SnmpAdminString textual convention that allows for use of the SNMPv3 View-Based Access Control Model (RFC 2575 [11], VACM) and allows an management application to identify its entries. The 2nd index, pingCtlTestName (also an SnmpAdminString), enables the same management application to have multiple outstanding requests." INDEX { pingCtlOwnerIndex, pingCtlTestName } ::= { pingCtlTable 1 } PingCtlEntry ::= SEQUENCE { pingCtlOwnerIndex SnmpAdminString, pingCtlTestName SnmpAdminString, pingCtlTargetAddressType HostAddressType, pingCtlTargetAddress HostAddress, pingCtlDataSize Unsigned32, pingCtlTimeOut Unsigned32, pingCtlProbeCount Unsigned32, pingCtlAdminStatus INTEGER, pingCtlDataFill OCTET STRING, pingCtlFrequency Unsigned32, pingCtlMaxRows Unsigned32, pingCtlStorageType StorageType, pingCtlTrapGeneration BITS, pingCtlTrapFilter Unsigned32, pingCtlType OBJECT IDENTIFIER, pingCtlDescr SnmpAdminString, pingCtlSourceAddress HostAddress, pingCtlIfIndex InterfaceIndexOrZero, pingCtlByPassRouteTable TruthValue, pingCtlDSField Unsigned32, pingCtlRowStatus RowStatus } pingCtlOwnerIndex OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "To facilitate the provisioning of access control by a security administrator using the View-Based Access Control Model (RFC 2575, VACM) for tables in which multiple users may need to independently create or modify entries, the initial index is used as an 'owner index'. Such an initial index has a syntax of SnmpAdminString, and can thus be trivially mapped to a securityName or groupName as defined in VACM, in accordance with a security policy. When used in conjunction with such a security policy all entries in the table belonging to a particular user (or group) will have the same value for this initial index. For a given user's entries in a particular table, the object identifiers for the information in these entries will have the same subidentifiers (except for the 'column' subidentifier) up to the end of the encoded owner index. To configure VACM to permit access to this portion of the table, one would create vacmViewTreeFamilyTable entries with the value of vacmViewTreeFamilySubtree including the owner index portion, and vacmViewTreeFamilyMask 'wildcarding' the column subidentifier. More elaborate configurations are possible." ::= { pingCtlEntry 1 } pingCtlTestName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The name of the ping test. This is locally unique, within the scope of an pingCtlOwnerIndex." ::= { pingCtlEntry 2 } pingCtlTargetAddressType OBJECT-TYPE SYNTAX HostAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the type of host address to be used at a remote host for performing a ping operation." DEFVAL { ipv4 } ::= { pingCtlEntry 3 } pingCtlTargetAddress OBJECT-TYPE SYNTAX HostAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the host address to be used at a remote host for performing a ping operation. The host address type is determined by the object value of corresponding pingCtlTargetAddressType. A value for this object MUST be set prior to transitioning its corresponding pingCtlEntry to active(1) via pingCtlRowStatus." ::= { pingCtlEntry 4 } pingCtlDataSize OBJECT-TYPE SYNTAX Unsigned32 (0..65507) UNITS "octets" MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the size of the data portion to be transmitted in a ping operation in octets. A ping request is usually an ICMP message encoded into an IP packet. An IP packet has a maximum size of 65535 octets. Subtracting the size of the ICMP or UDP header (both 8 octets) and the size of the IP header (20 octets) yields a maximum size of 65507 octets." DEFVAL { 0 } ::= { pingCtlEntry 5 } pingCtlTimeOut OBJECT-TYPE SYNTAX Unsigned32 (1..60) UNITS "seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the time-out value, in seconds, for a remote ping operation." DEFVAL { 3 } ::= { pingCtlEntry 6 } pingCtlProbeCount OBJECT-TYPE SYNTAX Unsigned32 (1..15) UNITS "probes" MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the number of times to perform a ping operation at a remote host." DEFVAL { 1 } ::= { pingCtlEntry 7 } pingCtlAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), -- test should be started disabled(2) -- test should be stopped } MAX-ACCESS read-create STATUS current DESCRIPTION "Reflects the desired state that a pingCtlEntry should be in: enabled(1) - Attempt to activate the test as defined by this pingCtlEntry. disabled(2) - Deactivate the test as defined by this pingCtlEntry. Refer to the corresponding pingResultsOperStatus to determine the operational state of the test defined by this entry." DEFVAL { disabled } ::= { pingCtlEntry 8 } pingCtlDataFill OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1024)) MAX-ACCESS read-create STATUS current DESCRIPTION "The content of this object is used together with the corresponding pingCtlDataSize value to determine how to fill the data portion of a probe packet. The option of selecting a data fill pattern can be useful when links are compressed or have data pattern sensitivities. The contents of pingCtlDataFill should be repeated in a ping packet when the size of the data portion of the ping packet is greater than the size of pingCtlDataFill." DEFVAL { '00'H } ::= { pingCtlEntry 9 } pingCtlFrequency OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The number of seconds to wait before repeating a ping test as defined by the value of the various objects in the corresponding row. A single ping test consists of a series of ping probes. The number of probes is determined by the value of the corresponding pingCtlProbeCount object. After a single test completes the number of seconds as defined by the value of pingCtlFrequency MUST elapse before the next ping test is started. A value of 0 for this object implies that the test as defined by the corresponding entry will not be repeated." DEFVAL { 0 } ::= { pingCtlEntry 10 } pingCtlMaxRows OBJECT-TYPE SYNTAX Unsigned32 UNITS "rows" MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum number of entries allowed in the pingProbeHistoryTable. An implementation of this MIB will remove the oldest entry in the pingProbeHistoryTable to allow the addition of an new entry once the number of rows in the pingProbeHistoryTable reaches this value. Old entries are not removed when a new test is started. Entries are added to the pingProbeHistoryTable until pingCtlMaxRows is reached before entries begin to be removed. A value of 0 for this object disables creation of pingProbeHistoryTable entries." DEFVAL { 50 } ::= { pingCtlEntry 11 } pingCtlStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "The storage type for this conceptual row. Conceptual rows having the value 'permanent' need not allow write-access to any columnar objects in the row." DEFVAL { nonVolatile } ::= { pingCtlEntry 12 } pingCtlTrapGeneration OBJECT-TYPE SYNTAX BITS { probeFailure(0), testFailure(1), testCompletion(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object determines when and if to to generation a notification for this entry: probeFailure(0) - Generate a pingProbeFailed notification subject to the value of pingCtlTrapFilter. pingCtlTrapFilter can be used to specify the number of successive probe failures that are required before a pingProbeFailed notification can be generated. testFailure(1) - Generate a pingTestFailed notification. In this instance pingCtlTrapFilter should specify the number of probe failures required in a test to have failed in order to considered the test as failed. testCompletion(2) - Generate a pingTestCompleted notification. The value of this object defaults to zero, indicating that none of the above options have been selected." ::= { pingCtlEntry 13 } pingCtlTrapFilter OBJECT-TYPE SYNTAX Unsigned32 (0..15) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object is used to determine when to generate either a pingProbeFailed or a pingTestFailed NOTIFICATION. Which NOTIFICATION to generate is determined by the value of pingCtlTrapGeneration. Setting pingCtlTrapGeneration to probeFailure(2) implies that a pingProbeFailed NOTIFICATION is generated only when the number of successive probe failures as indicated by the value of pingCtlTrapFilter fail within a given ping test. Setting pingCtlTrapGeneration to testFailure(3) implies that a pingTestFailed NOTIFICATION is generated only when the number of ping failures within a test exceed the value of pingCtlTrapFilter." DEFVAL { 1 } ::= { pingCtlEntry 14 } pingCtlType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object is used to either report or select the implementation method to be used for calculating a ping response time. The value of this object MAY be selected from pingImplementationTypeDomains. Additional implementation types SHOULD be allocated as required by implementers of the DISMAN-PING-MIB under their enterprise specific registration point and not beneath pingImplementationTypeDomains." DEFVAL { pingIcmpEcho } ::= { pingCtlEntry 15 } pingCtlDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-create STATUS current DESCRIPTION "The purpose of this object is to provide a descriptive name of the remote ping test." DEFVAL { '00'H } ::= { pingCtlEntry 16 } pingCtlSourceAddress OBJECT-TYPE SYNTAX HostAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Use the specified IP address (which must be given as an IP number, not a hostname) as the source address in outgoing probe packets. On hosts with more than one IP address, this option can be used to force the source address to be something other than the primary IP address of the interface the probe packet is sent on. If the IP address is not one of this machine's interface addresses, an error is returned and nothing is sent. A zero length octet string value for this object disables source address specification. The address type (HostAddressType) that relates to this object is specified by the corresponding value of pingCtlTargetAddressType." DEFVAL { ''H } ::= { pingCtlEntry 17 } pingCtlIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "Setting this object to an interface's ifIndex prior to starting a remote ping operation directs the ping probes to be transmitted over the specified interface. A value of zero for this object implies that this option is not enabled." DEFVAL { 0 } ::= { pingCtlEntry 18 } pingCtlByPassRouteTable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The purpose of this object is to optionally enable bypassing the route table. If enabled, the remote host will bypass the normal routing tables and send directly to a host on an attached network. If the host is not on a directly-attached network, an error is returned. This option can be used to perform the ping operation to a local host through an interface that has no route defined (e.g., after the interface was dropped by routed)." DEFVAL { false } ::= { pingCtlEntry 19 } pingCtlDSField OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the value to store in the Differentiated Services (DS) Field in the IP packet used to encapsulate the ping probe. The DS Field is defined as the Type of Service (TOS) octet in a IPv4 header or as the Traffic Class octet in a IPv6 header. The value of this object must be a decimal integer in the range from 0 to 255. This option can be used to determine what effect an explicit DS Field setting has on a ping response. Not all values are legal or meaningful. DS Field usage is often not supported by IP implementations and not all values are supported. Refer to RFC 2474 for guidance on usage of this field." REFERENCE "Refer to RFC 2474 for the definition of the Differentiated Services Field and to RFC 1812 Section 5.3.2 for Type of Service (TOS)." DEFVAL { 0 } ::= { pingCtlEntry 20 } pingCtlRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object allows entries to be created and deleted in the pingCtlTable. Deletion of an entry in this table results in all corresponding (same pingCtlOwnerIndex and pingCtlTestName index values) pingResultsTable and pingProbeHistoryTable entries being deleted. A value MUST be specified for pingCtlTargetAddress prior to a transition to active(1) state being accepted. Activation of a remote ping operation is controlled via pingCtlAdminStatus and not by transitioning of this object's value to active(1). Transitions in and out of active(1) state are not allowed while an entry's pingResultsOperStatus is active(1) with the exception that deletion of an entry in this table by setting its RowStatus object to destroy(6) will stop an active ping operation. The operational state of a ping operation can be determined by examination of its pingResultsOperStatus object." REFERENCE "RFC 2579, 'Textual Conventions for SMIv2.'" ::= { pingCtlEntry 21 } -- Ping Results Table pingResultsTable OBJECT-TYPE SYNTAX SEQUENCE OF PingResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the Ping Results Table for providing the capability of performing ping operations at a remote host. The results of these operations are stored in the pingResultsTable and the pingPastProbeTable. An entry is added to the pingResultsTable when an pingCtlEntry is started by successful transition of its pingCtlAdminStatus object to enabled(1). An entry is removed from the pingResultsTable when its corresponding pingCtlEntry is deleted." ::= { pingObjects 3 } pingResultsEntry OBJECT-TYPE SYNTAX PingResultsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the pingResultsTable. The pingResultsTable has the same indexing as the pingCtlTable in order for a pingResultsEntry to correspond to the pingCtlEntry that caused it to be created." INDEX { pingCtlOwnerIndex, pingCtlTestName } ::= { pingResultsTable 1 } PingResultsEntry ::= SEQUENCE { pingResultsOperStatus INTEGER, pingResultsIpTargetAddress IpHostAddress, pingResultsMinRtt Unsigned32, pingResultsMaxRtt Unsigned32, pingResultsAverageRtt Unsigned32, pingResultsProbeResponses Counter32, pingResultsSentProbes Counter32, pingResultsRttSumOfSquares Unsigned32, pingResultsLastGoodProbe DateAndTime } pingResultsOperStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), -- test is in progress disabled(2) -- test has stopped } MAX-ACCESS read-only STATUS current DESCRIPTION "Reflects the operational state of a pingCtlEntry: enabled(1) - Test is active. disabled(2) - Test has stopped." ::= { pingResultsEntry 1 } pingResultsIpTargetAddress OBJECT-TYPE SYNTAX IpHostAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This objects reports the IP address associated with a pingCtlTargetAddress value when the destination address is specified as a DNS name. The value of this object should be a zero length octet string when a DNS name is not specified or when a specified DNS name fails to resolve." ::= { pingResultsEntry 2 } pingResultsMinRtt OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received." ::= { pingResultsEntry 3 } pingResultsMaxRtt OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received." ::= { pingResultsEntry 4 } pingResultsAverageRtt OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The current average ping round-trip-time (RTT)." ::= { pingResultsEntry 5 } pingResultsProbeResponses OBJECT-TYPE SYNTAX Counter32 UNITS "responses" MAX-ACCESS read-only STATUS current DESCRIPTION "Number of responses received for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probe responses have been received." ::= { pingResultsEntry 6 } pingResultsSentProbes OBJECT-TYPE SYNTAX Counter32 UNITS "probes" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object reflects the number of probes sent for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probes have been sent." ::= { pingResultsEntry 7 } pingResultsRttSumOfSquares OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the sum of the squares for all ping responses received. Its purpose is to enable standard deviation calculation. The value of this object MUST be reported as 0 when no ping responses have been received." ::= { pingResultsEntry 8 } pingResultsLastGoodProbe OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Date and time when the last response was received for a probe." ::= { pingResultsEntry 9 } -- Ping Probe History Table pingProbeHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF PingProbeHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines a table for storing the results of a ping operation. Entries in this table are limited by the value of the corresponding pingCtlMaxRows object. An entry in this table is created when the result of a ping probe is determined. The initial 2 instance identifier index values identify the pingCtlEntry that a probe result (pingProbeHistoryEntry) belongs to. An entry is removed from this table when its correspoding pingCtlEntry is deleted. An implementation of this MIB will remove the oldest entry in the pingProbeHistoryTable to allow the addition of an new entry once the number of rows in the pingProbeHistoryTable reaches the value specified by pingCtlMaxRows." ::= { pingObjects 4 } pingProbeHistoryEntry OBJECT-TYPE SYNTAX PingProbeHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the pingProbeHistoryTable. The first two index elements identify the pingCtlEntry that a pingProbeHistoryEntry belongs to. The 3rd index element selects a single probe result." INDEX { pingCtlOwnerIndex, pingCtlTestName, pingProbeHistoryIndex } ::= { pingProbeHistoryTable 1 } PingProbeHistoryEntry ::= SEQUENCE { pingProbeHistoryIndex Unsigned32, pingProbeHistoryResponse Unsigned32, pingProbeHistoryStatus OperationResponseStatus, pingProbeHistoryLastRC Integer32, pingProbeHistoryTime DateAndTime } pingProbeHistoryIndex OBJECT-TYPE SYNTAX Unsigned32 (1..'ffffffff'h) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created when the result of a ping probe is determined. The initial 2 instance identifier index values identify the pingCtlEntry that a probe result (pingProbeHistoryEntry) belongs to. An implementation MUST start assigning pingProbeHistoryIndex values at 1 and wrap after exceeding the maximum possible value as defined by the limit of this object ('ffffffff'h)." ::= { pingProbeHistoryEntry 1 } pingProbeHistoryResponse OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of time measured in milliseconds from when a probe was sent to when its response was received or when it timed out. The value of this object is reported as 0 when it is not possible to transmit a probe." ::= { pingProbeHistoryEntry 2 } pingProbeHistoryStatus OBJECT-TYPE SYNTAX OperationResponseStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The result of a ping operation made by a remote host for a particular probe." ::= { pingProbeHistoryEntry 3 } pingProbeHistoryLastRC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The last implementation method specific reply code received. If the ICMP Echo capability is being used then a successful probe ends when an ICMP response is received that contains the code ICMP_ECHOREPLY(0). The ICMP responses are defined normally in the ip_icmp include file." ::= { pingProbeHistoryEntry 4 } pingProbeHistoryTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp for when this probe result was determined." ::= { pingProbeHistoryEntry 5 } -- Notification Definition section pingProbeFailed NOTIFICATION-TYPE OBJECTS { pingCtlTargetAddressType, pingCtlTargetAddress, pingResultsOperStatus, pingResultsIpTargetAddress, pingResultsMinRtt, pingResultsMaxRtt, pingResultsAverageRtt, pingResultsProbeResponses, pingResultsSentProbes, pingResultsRttSumOfSquares, pingResultsLastGoodProbe } STATUS current DESCRIPTION "Generated when a probe failure is detected when the corresponding pingCtlTrapGeneration object is set to probeFailure(2) subject to the value of pingCtlTrapFilter. pingCtlTrapFilter can be used to specify the number of successive probe failures that are required before this notification can be generated." ::= { pingNotifications 1 } pingTestFailed NOTIFICATION-TYPE OBJECTS { pingCtlTargetAddressType, pingCtlTargetAddress, pingResultsOperStatus, pingResultsIpTargetAddress, pingResultsMinRtt, pingResultsMaxRtt, pingResultsAverageRtt, pingResultsProbeResponses, pingResultsSentProbes, pingResultsRttSumOfSquares, pingResultsLastGoodProbe } STATUS current DESCRIPTION "Generated when a ping test is determined to have failed when the corresponding pingCtlTrapGeneration object is set to testFailure(3). In this instance pingCtlTrapFilter should specify the number of probe failures required in a test to have failed in order to considered the test as failed." ::= { pingNotifications 2 } pingTestCompleted NOTIFICATION-TYPE OBJECTS { pingCtlTargetAddressType, pingCtlTargetAddress, pingResultsOperStatus, pingResultsIpTargetAddress, pingResultsMinRtt, pingResultsMaxRtt, pingResultsAverageRtt, pingResultsProbeResponses, pingResultsSentProbes, pingResultsRttSumOfSquares, pingResultsLastGoodProbe } STATUS current DESCRIPTION "Generated at the completion of a ping test when the corresponding pingCtlTrapGeneration object is set to testCompletion(4)." ::= { pingNotifications 3 } -- Conformance information -- Compliance statements pingCompliances OBJECT IDENTIFIER ::= { pingConformance 1 } pingGroups OBJECT IDENTIFIER ::= { pingConformance 2 } -- Compliance statements pingCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the DISMAN-PING-MIB." MODULE -- this module MANDATORY-GROUPS { pingGroup, pingNotificationsGroup } GROUP pingTimeStampGroup DESCRIPTION "This group is mandatory for implementations that have access to a system clock and are capable of setting the values for DateAndTime objects. It is RECOMMENDED that when this group is not supported that the values for the objects in this group be reported as '0000000000000000'H." OBJECT pingMaxConcurrentRequests MIN-ACCESS read-only DESCRIPTION "The agent is not required to support a SET operation to this object." OBJECT pingCtlStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required. It is also allowed for implementations to support only the volatile StorageType enumeration." OBJECT pingCtlType MIN-ACCESS read-only DESCRIPTION "Write access is not required. In addition, the only value that MUST be supported by an implementation is pingIcmpEcho." OBJECT pingCtlByPassRouteTable MIN-ACCESS read-only DESCRIPTION "This object is not required by implementations that are not capable of its implementation. The function represented by this object is implementable if the setsockopt SOL_SOCKET SO_DONTROUTE option is supported." OBJECT pingCtlSourceAddress MIN-ACCESS read-only DESCRIPTION "This object is not required by implementations that are not capable of binding the send socket with a source address." OBJECT pingCtlIfIndex MIN-ACCESS read-only DESCRIPTION "Write access is not required. When write access is not supported return a 0 as the value of this object. A value of 0 implies that the function represented by this option is not supported." OBJECT pingCtlDSField MIN-ACCESS read-only DESCRIPTION "Write access is not required. When write access is not supported return a 0 as the value of this object. A value of 0 implies that the function represented by this option is not supported." ::= { pingCompliances 1 } -- MIB groupings pingGroup OBJECT-GROUP OBJECTS { pingMaxConcurrentRequests, pingCtlTargetAddressType, pingCtlTargetAddress, pingCtlDataSize, pingCtlTimeOut, pingCtlProbeCount, pingCtlAdminStatus, pingCtlDataFill, pingCtlFrequency, pingCtlMaxRows, pingCtlStorageType, pingCtlTrapGeneration, pingCtlTrapFilter, pingCtlType, pingCtlDescr, pingCtlByPassRouteTable, pingCtlSourceAddress, pingCtlIfIndex, pingCtlDSField, pingCtlRowStatus, pingResultsOperStatus, pingResultsIpTargetAddress, pingResultsMinRtt, pingResultsMaxRtt, pingResultsAverageRtt, pingResultsProbeResponses, pingResultsSentProbes, pingResultsRttSumOfSquares, pingProbeHistoryResponse, pingProbeHistoryStatus, pingProbeHistoryLastRC } STATUS current DESCRIPTION "The group of objects that comprise the remote ping capability." ::= { pingGroups 1 } pingTimeStampGroup OBJECT-GROUP OBJECTS { pingResultsLastGoodProbe, pingProbeHistoryTime } STATUS current DESCRIPTION "The group of DateAndTime objects." ::= { pingGroups 2 } pingNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { pingProbeFailed, pingTestFailed, pingTestCompleted } STATUS current DESCRIPTION "The notification which are required to be supported by implementations of this MIB." ::= { pingGroups 3 } END -- -- Copyright (C) The Internet Society (1999). All Rights Reserved. -- This document and translations of it may be copied and furnished to -- others, and derivative works that comment on or otherwise explain it or -- assist in its implementation may be prepared, copied, published and -- distributed, in whole or in part, without restriction of any kind, -- provided that the above copyright notice and this paragraph are included -- on all such copies and derivative works. However, this document itself -- may not be modified in any way, such as by removing the copyright notice -- or references to the Internet Society or other Internet organizations, -- except as needed for the purpose of developing Internet standards in -- which case the procedures for copyrights defined in the Internet -- Standards process must be followed, or as required to translate it into -- languages other than English. -- -- The limited permissions granted above are perpetual and will not be -- revoked by the Internet Society or its successors or assigns. -- -- This document and the information contained herein is provided on an "AS -- IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK -- FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT -- LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT -- INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR -- FITNESS FOR A PARTICULAR PURPOSE.