-- extracted from draft-ietf-hubmib-efm-epon-mib-02.txt -- at Thu Sep 30 06:23:30 2004 EPON-DEVICE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, mib-2, OBJECT-TYPE, Counter32, Unsigned32, Integer32, zeroDotZero FROM SNMPv2-SMI TruthValue, DateAndTime, RowStatus, MacAddress FROM SNMPv2-TC ifIndex FROM IF-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF SnmpAdminString FROM SNMP-FRAMEWORK-MIB ; eponDeviceMIB MODULE-IDENTITY LAST-UPDATED "200409210000Z" -- September 21, 2004 ORGANIZATION "IETF Ethernet Interfaces and Hub MIB Working Group" CONTACT-INFO "WG charter: http://www.ietf.org/html.charters/hubmib-charter.html Mailing Lists: General Discussion: hubmib@ietf.org To Subscribe: hubmib-request@ietf.org In Body: subscribe your_email_address Chair: Dan Romascanu Postal: Avaya Inc. Atidim Technology Park, Bldg. 3 Tel Aviv 61131 Israel Tel: +972-3-645-8414 E-mail: dromasca@avaya.com Editor: Lior Khermosh Postal: Passave Technologies Inc. Ackerstein Towers, Tower A, 6th floor, 9 Hamenofim St. Hertzliya Pituach 46725, ISRAEL P.O.Box 2089 Hertzliya Pituach 46120 Israel Tel: +972-9-9717600 Ext: 7181 E-mail: lior.khermosh@passave.com" DESCRIPTION "The objects in this MIB module are used to manage Ethernet Passive Optical Network (EPON) devices which are based on the Ethernet in the First Mile (EFM) PON as defined in IEEE Draft P802.3ah/D3.0 clause 60,64,65. The following reference is used throughout this MIB module: [802.3ah] refers to: IEEE Draft P802.3ah/D3.3: 'Draft amendment to - Information technology - Telecommunications and information exchange between systems - Local and metropolitan area networks - Specific requirements - Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications - Media Access Control Parameters, Physical Layers and Management Parameters for subscriber access networks', 22 April 2004. Of particular interest are Clause 64(MPCP) 65(P2mP RS) and 60 (PON PMDs). Clause 30, 'Management', and Clause 45,'Management Data Input/Output (MDIO) Interface'. Copyright (C) The Internet Society (2004). This version of this MIB module is part of XXXX see the RFC itself for full legal notices." -- Editor's Note: Replace XXXX with the actual RFC number -- assigned by RFC Editor and remove this note REVISION "200409210000Z" -- September 21, 2004 DESCRIPTION "Initial version, published as RFC XXXX." ::= { mib-2 XXX } -- Editor's Note: Replace XXX with a real OID once it is -- assigned by IANA and remove this note. eponDeviceObjectMIB OBJECT IDENTIFIER ::= { eponDeviceMIB 1} eponDeviceObjects OBJECT IDENTIFIER ::= { eponDeviceObjectMIB 1} eponDeviceConformance OBJECT IDENTIFIER ::= { eponDeviceObjectMIB 2} eponDeviceControlObjects OBJECT IDENTIFIER ::= { eponDeviceObjects 1} eponDeviceStatObjects OBJECT IDENTIFIER ::= { eponDeviceObjects 2} eponDeviceEventObjects OBJECT IDENTIFIER ::= { eponDeviceObjects 3} eponDeviceControlTable OBJECT-TYPE SYNTAX SEQUENCE OF EponDeviceControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for EPON device MIB modules." ::= { eponDeviceControlObjects 1 } eponDeviceControlEntry OBJECT-TYPE SYNTAX EponDeviceControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the EPON device Control table." INDEX { ifIndex } ::= { eponDeviceControlTable 1 } EponDeviceControlEntry ::= SEQUENCE { eponDeviceObjectReset INTEGER, eponDeviceObjectModes INTEGER, eponDeviceObjectFecEnabled INTEGER, eponDeviceObjectOamMode INTEGER, eponDeviceObjectDeviceReadyMode INTEGER, eponDeviceObjectPowerDown TruthValue, eponDeviceObjectNumberOfLLIDs Integer32, eponDeviceObjectReportThreshold Integer32, eponDeviceRemoteMACAddressLLIDControl INTEGER } eponDeviceObjectReset OBJECT-TYPE SYNTAX INTEGER { running(1), reset(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to reset the EPON device. The interface may be unavailable while the reset occurs and data may be lost. During reading operation it returns the state of the EPON device. running(1) indicates and operates normal operation, reset(2) indicates and operates reset mode. Writing can be done all the time." DEFVAL { 1 } ::= { eponDeviceControlEntry 1 } eponDeviceObjectModes OBJECT-TYPE SYNTAX INTEGER { olt(1), onu(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable defines the mode of the EPON device. When an olt(1) it is an Optical Line Terminal device (server) and when an onu(2) and Optical Network Unit device (client)" ::= { eponDeviceControlEntry 2 } eponDeviceObjectFecEnabled OBJECT-TYPE SYNTAX INTEGER { noFecEnabled (1), fecTxEnabled (2), fecRxEnabled (3), fecTxRxEnabled (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines and provides information whether the EPON device uses FEC as defined in the [802.3ah] clause 65.2 for EPON. When noFECEnabled(1) the device does not support FEC mode When fecTxEnabled(2) the device supports the FEC transmission mode. When fecRxEnabled(3) the device supports the FEC Receive mode. When fecTxRxEnabled(4) the device supports the FEC transmission and receive mode. Writing can be done all the time. This attribute is relevant for an OLT and an ONU." DEFVAL { 1 } ::= { eponDeviceControlEntry 4 } eponDeviceObjectOamMode OBJECT-TYPE SYNTAX INTEGER { noOam (1), oamServer (2), oamclient (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines and provides information on the Operation Administration and Maintenance (OAM) mode of an EPON device as defined by the [802.3ah] clause 57. When noOam(1) the device does not supports the OAM mode. When oamServer(2) the device supports the OAM mode as a server unit. When oamClient(3) the device supports the OAM mode as a client unit. Writing can be done during initialization, eponDeviceObjectDeviceReadyMode is in notReady(1) or inProcess(2). This attribute is relevant for an OLT and an ONU." DEFVAL { 1 } ::= { eponDeviceControlEntry 5 } eponDeviceObjectDeviceReadyMode OBJECT-TYPE SYNTAX INTEGER { notReady (1), inProcess (2), ready (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the mode of an EPON device and provides information on the mode in initialization - ready for registration as defined by the [802.3ah] clause 64. When notReady(1) the device is not ready for operation. When inProcess(2) the device is in initialization process. When ready(3) the device is ready for registration. Writing can be done all the time. This attribute is relevant for an OLT and an ONU." DEFVAL { 1 } ::= { eponDeviceControlEntry 6 } eponDeviceObjectPowerDown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this variable to True(1) will cause Device to be entered into Power down mode where no registration is allowed and only receiving data from the link. Writing can be done all the time. This attribute is relevant for an OLT and an ONU." DEFVAL { false } ::= { eponDeviceControlEntry 7 } eponDeviceObjectNumberOfLLIDs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A read only variable which defines the number of registered LLIDs (as defined by the [802.3ah] clause 65) in a EPON network for an OLT and an ONU. Initialization value is 0. This attribute is relevant for an OLT and an ONU." ::= { eponDeviceControlEntry 8 } eponDeviceObjectReportThreshold OBJECT-TYPE SYNTAX Integer32 UNITS "TQ (16nsec)" MAX-ACCESS read-write STATUS current DESCRIPTION "A set of 8 integers, for each LLID, that defines the threshold reporting for each Queue in the REPORT message, as defined in [802.3ah] 64. First Queue set reporting will provide information on the queue occupancy of frames below this Threshold. The value returned shall be in Time quanta (TQ) which is 16nsec or 2 octets increments. Writing can be done all the time. This attribute is relevant for an OLT and an ONU." DEFVAL { 0 } ::= { eponDeviceControlEntry 9 } eponDeviceRemoteMACAddressLLIDControl OBJECT-TYPE SYNTAX INTEGER { none(1), resetLog(2), useDefaultReporting(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates and controls the resetting of the LLID MAC address log. Setting this object to none(1) has no action resetLog(2) empties the LLID MAC address log. All data is deleted. Setting it to useDefaultReporting(3) returns all entries priorities to their factory-default reporting. Reading this object always returns useDefaultReporting(3)." DEFVAL { 3 } ::= { eponDeviceControlEntry 10 } eponDeviceRemoteMACAddressLLIDTable OBJECT-TYPE SYNTAX SEQUENCE OF EponDeviceRemoteMACAddressLLIDEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of read-only value that identifies the source_address and LLIDs parameter of the remote devices in the network. This MacAddress value, as defined in [802.3ah], 30.3.5.1.5, is updated on reception of a valid frame with a unicast destination Field or (1) a destination Field equal to the reserved multicast address for MAC Control specified in [802.3ah] Annex 31A, (2) lengthOrType field value equal to the reserved Type for MAC Control as specified in [802.3ah] Annex 31A. (3)an MPCP subtype value equal to the subtype reserved for MPCP as specified in [802.3ah] Annex 31A, and an LLID as allocated by the OLT. The table is defined as Remote MAC address - LLID (RMadL) The table is relevant only for an OLT device, and is equivalent from a bridge emulation to the bridge port-MAC address table where the LLIDs are equivalent to virtual bridge ports." ::= { eponDeviceControlObjects 2 } eponDeviceRemoteMACAddressLLIDEntry OBJECT-TYPE SYNTAX EponDeviceRemoteMACAddressLLIDEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A group of entries. Applications create and delete entries using eponDeviceRMadlEntryStatus. When adding objects to an LLID they are added in the persistent order of their index in this table." INDEX {ifIndex } ::= { eponDeviceRemoteMACAddressLLIDTable 1 } EponDeviceRemoteMACAddressLLIDEntry ::= SEQUENCE { eponDeviceRemoteMACAddressLLIDName SnmpAdminString, eponDeviceRMadlLLID Unsigned32, eponDeviceRMadlLogID OBJECT IDENTIFIER, eponDeviceRMadlRemoteAddress MacAddress, eponDeviceRMadlType INTEGER, eponDeviceRMadlAction INTEGER, eponDeviceRMadlEntryStatus RowStatus } eponDeviceRemoteMACAddressLLIDName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A locally-unique, administratively assigned name for a group of entries." ::= { eponDeviceRemoteMACAddressLLIDEntry 1 } eponDeviceRMadlLLID OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "An arbitrary integer for the purpose of identifying the LLID. Writing can be done all the time." DEFVAL { 1 } ::= { eponDeviceRemoteMACAddressLLIDEntry 2 } eponDeviceRMadlLogID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "The object identifier of a MIB module object to add to an entry, indicating the entry ID in the table. Writing can be done all the time." DEFVAL { zeroDotZero } ::= { eponDeviceRemoteMACAddressLLIDEntry 3 } eponDeviceRMadlRemoteAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The remote MAC address of the LLID. Writing can be done all the time." ::= { eponDeviceRemoteMACAddressLLIDEntry 4 } eponDeviceRMadlType OBJECT-TYPE SYNTAX INTEGER { notRegister (1), registered (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "A list of types for entries - LLIDs. Indicates and defines the state of registration. notRegister(1) marks a non registered LID, registered(2) marks a registered LLID. Writing can be done all the time." DEFVAL { 1 } ::= { eponDeviceRemoteMACAddressLLIDEntry 5 } eponDeviceRMadlAction OBJECT-TYPE SYNTAX INTEGER { none (1), register (2), deregister (3), reregister (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "A list of actions for an entry - LLID. Indicates and defines the state of registration for the remote device. none(1) marks no action, register(2) marks to register an LLID, deregister(3) marks to deregister an LLID, reregister(4) marks reregistered LLID. Writing can be done all the time." DEFVAL { 1 } ::= { eponDeviceRemoteMACAddressLLIDEntry 6 } eponDeviceRMadlEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The control that allows creation and deletion of entries. Once made active an entry MAY not be modified except to delete it." ::= { eponDeviceRemoteMACAddressLLIDEntry 7 } --Statistics tables eponDeviceStatTable OBJECT-TYPE SYNTAX SEQUENCE OF EponDeviceStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the list of statistics counters of EPON devices. The attributes are relevant for an OLT and an ONU." ::= { eponDeviceStatObjects 1} eponDeviceStatEntry OBJECT-TYPE SYNTAX EponDeviceStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries for Table of statistics counters of EPON devices." INDEX { ifIndex } ::= { eponDeviceStatTable 1 } EponDeviceStatEntry::= SEQUENCE { eponDeviceStatTxFramesQueue0 Counter32, eponDeviceStatTxFramesQueue1 Counter32, eponDeviceStatTxFramesQueue2 Counter32, eponDeviceStatTxFramesQueue3 Counter32, eponDeviceStatTxFramesQueue4 Counter32, eponDeviceStatTxFramesQueue5 Counter32, eponDeviceStatTxFramesQueue6 Counter32, eponDeviceStatTxFramesQueue7 Counter32, eponDeviceStatRxFramesQueue0 Counter32, eponDeviceStatRxFramesQueue1 Counter32, eponDeviceStatRxFramesQueue2 Counter32, eponDeviceStatRxFramesQueue3 Counter32, eponDeviceStatRxFramesQueue4 Counter32, eponDeviceStatRxFramesQueue5 Counter32, eponDeviceStatRxFramesQueue6 Counter32, eponDeviceStatRxFramesQueue7 Counter32, eponDeviceStatDroppedFramesQueue0 Counter32, eponDeviceStatDroppedFramesQueue1 Counter32, eponDeviceStatDroppedFramesQueue2 Counter32, eponDeviceStatDroppedFramesQueue3 Counter32, eponDeviceStatDroppedFramesQueue4 Counter32, eponDeviceStatDroppedFramesQueue5 Counter32, eponDeviceStatDroppedFramesQueue6 Counter32, eponDeviceStatDroppedFramesQueue7 Counter32 } eponDeviceStatTxFramesQueue0 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-0- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-0-. The -Queue-0- marking matched the REPORT MPCP message Queue-0 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 1} eponDeviceStatTxFramesQueue1 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-1- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-1-. The -Queue-1- marking matched the REPORT MPCP message Queue-1 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 2} eponDeviceStatTxFramesQueue2 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-2- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-2-. The -Queue-2- marking matched the REPORT MPCP message Queue-2 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 3} eponDeviceStatTxFramesQueue3 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-3- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-3-. The -Queue-3- marking matched the REPORT MPCP message Queue-3 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 4} eponDeviceStatTxFramesQueue4 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-4- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-4-. The -Queue-4- marking matched the REPORT MPCP message Queue-4 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 5} eponDeviceStatTxFramesQueue5 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-5- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-5-. The -Queue-5- marking matched the REPORT MPCP message Queue-5 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 6} eponDeviceStatTxFramesQueue6 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-6- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-6-. The -Queue-6- marking matched the REPORT MPCP message Queue-6 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 7} eponDeviceStatTxFramesQueue7 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-7- frames transmission occurs. Increment the counter by one for each frame transmitted which is an output of -Queue-7-. The -Queue-7- marking matched the REPORT MPCP message Queue-7 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 8} eponDeviceStatRxFramesQueue0 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-0- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-0-. The -Queue-0- marking matched the REPORT MPCP message Queue-0 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { eponDeviceStatEntry 9} eponDeviceStatRxFramesQueue1 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-1- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-1-. The -Queue-1- marking matched the REPORT MPCP message Queue-1 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { eponDeviceStatEntry 10} eponDeviceStatRxFramesQueue2 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-2- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-2-. The -Queue-2- marking matched the REPORT MPCP message Queue-2 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { eponDeviceStatEntry 11} eponDeviceStatRxFramesQueue3 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-3- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-3-. The -Queue-3- marking matched the REPORT MPCP message Queue-3 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { eponDeviceStatEntry 12} eponDeviceStatRxFramesQueue4 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-4- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-4-. The -Queue-4- marking matched the REPORT MPCP message Queue-4 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { eponDeviceStatEntry 13} eponDeviceStatRxFramesQueue5 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-5- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-5-. The -Queue-5- marking matched the REPORT MPCP message Queue-5 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { eponDeviceStatEntry 14} eponDeviceStatRxFramesQueue6 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-6- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-6-. The -Queue-6- marking matched the REPORT MPCP message Queue-6 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { eponDeviceStatEntry 15} eponDeviceStatRxFramesQueue7 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-7- frames reception occurs. A single counter at the ONU and a set of counters, one for each LLID, at the OLT. Increment the counter by one for each frame received for each LLID, which is an output of -Queue-7-. The -Queue-7- marking matched the REPORT MPCP message Queue-7 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU and an OLT." ::= { eponDeviceStatEntry 16} eponDeviceStatDroppedFramesQueue0 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-0- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-0-. The -Queue-0- marking matched the REPORT MPCP message Queue-0 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 17} eponDeviceStatDroppedFramesQueue1 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-1- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-1-. The -Queue-1- marking matched the REPORT MPCP message Queue-1 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 18} eponDeviceStatDroppedFramesQueue2 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-2- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-2-. The -Queue-2- marking matched the REPORT MPCP message Queue-2 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 19} eponDeviceStatDroppedFramesQueue3 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-3- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-3-. The -Queue-3- marking matched the REPORT MPCP message Queue-3 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 20} eponDeviceStatDroppedFramesQueue4 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-4- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-4-. The -Queue-4- marking matched the REPORT MPCP message Queue-4 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 21} eponDeviceStatDroppedFramesQueue5 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-5- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-5-. The -Queue-5- marking matched the REPORT MPCP message Queue-5 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 22} eponDeviceStatDroppedFramesQueue6 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-6- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-6-. The -Queue-6- marking matched the REPORT MPCP message Queue-6 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 23} eponDeviceStatDroppedFramesQueue7 OBJECT-TYPE SYNTAX Counter32 UNITS "frames" MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times a -Queue-7- frames drops occurs. Increment the counter by one for each frame dropped from -Queue-7-. The -Queue-7- marking matched the REPORT MPCP message Queue-7 field, as defined in [802.3ah] clause 64. This counter is mandatory for an ONU." ::= { eponDeviceStatEntry 24} --Editor's Note use reference to event MIB modules [RFC2981] and --docsis MIB modules [RFC2669] eponDeviceEventObjectTable OBJECT-TYPE SYNTAX SEQUENCE OF EponDeviceEventObjectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the Event Objects for EPON devices. The attributes are relevant for an OLT and an ONU." ::= { eponDeviceEventObjects 1} eponDeviceEventObjectEntry OBJECT-TYPE SYNTAX EponDeviceEventObjectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries for Table of Event objects for EPON devices." INDEX { ifIndex } ::= { eponDeviceEventObjectTable 1 } EponDeviceEventObjectEntry::= SEQUENCE { eponDeviceSampleMinimum Integer32, eponDeviceDyingGaspAlarmState TruthValue, eponDeviceDyingGaspAlarmEnabled TruthValue, eponDeviceCriticalEventState TruthValue, eponDeviceCriticalEventEnabled TruthValue, eponDeviceLocalLinkFaultAlarmState TruthValue, eponDeviceLocalLinkFaultAlarmEnabled TruthValue, eponDeviceTemperatureEventIndicationState TruthValue, eponDeviceTemperatureEventIndicationEnabled TruthValue, eponDevicePowerVoltageEventIndicationState TruthValue, eponDevicePowerVoltageEventIndicationEnabled TruthValue, eponDeviceGlobalEventState TruthValue, eponDeviceGlobalEventEnabled TruthValue, eponDeviceErroredSymbolPeriodEventState TruthValue, eponDeviceErroredSymbolPeriodEventEnabled TruthValue, eponDeviceErroredFrameEventState TruthValue, eponDeviceErroredFrameEventEnabled TruthValue, eponDeviceErroredFramePeriodEventState TruthValue, eponDeviceErroredFramePeriodEventEnabled TruthValue, eponDeviceErroredFrameSecondsSummaryEventState TruthValue, eponDeviceErroredFrameSecondsSummaryEventEnabled TruthValue, eponDeviceOrganizationSpecificEventState TruthValue, eponDeviceOrganizationSpecificEventEnabled TruthValue, eponDeviceEventControl INTEGER } eponDeviceSampleMinimum OBJECT-TYPE SYNTAX Integer32 (1..2147483647) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum Frequency of events this system will accept. A system may use the larger values of this minimum to lessen the impact of constant sampling. For larger sampling intervals the system samples less often and suffers less overhead. Unless explicitly resource limited, a system's value for this object SHOULD be 1, allowing as small as a 1 second interval for ongoing trigger sampling. Writing of the value can be done all the time." DEFVAL { 1 } ::= { eponDeviceEventObjectEntry 1 } eponDeviceDyingGaspAlarmState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Dying Gasp indication of the OAM alarm indications as described in the [802.3ah] clause 57. When true the device has a dying gasp alarm asserted. When false the dying gasp alarm is reset " ::= { eponDeviceEventObjectEntry 2} eponDeviceDyingGaspAlarmEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow DyingGaspAlarm event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 3 } eponDeviceCriticalEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Critical Event indication of the OAM alarm indications as described in the [802.3ah] clause 57. When true the device has a Critical Event asserted. When false the Critical Event is reset." ::= { eponDeviceEventObjectEntry 4 } eponDeviceCriticalEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow CriticalEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 5 } eponDeviceLocalLinkFaultAlarmState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Local Link Fault indication of the OAM alarm indications as described in the [802.3ah] clause 57. When true the device has a Local Link Fault alarm asserted. When false the Local Link Fault alarm is reset." ::= { eponDeviceEventObjectEntry 6 } eponDeviceLocalLinkFaultAlarmEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow LocalLinkFaultAlarm event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 7 } eponDeviceTemperatureEventIndicationState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Temperature Event indication of an EPON device. When condition of box temperature is above the threshold defined the alarm is asserted. When the condition is below that threshold the alarm is de-asserted. When true the device has a Temperature Event Indication asserted. When false the Temperature Event Indication is reset." ::= { eponDeviceEventObjectEntry 8 } eponDeviceTemperatureEventIndicationEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow TemperatureEventIndication event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 9 } eponDevicePowerVoltageEventIndicationState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Power/Voltage Event Indication of an EPON device. When condition of box Power/voltage is above the threshold defined the alarm is asserted. When the condition is below that threshold the alarm is de-asserted. When true the device has a Power/Voltage Event Indication asserted. When false the Power/Voltage Event Indication is reset. " ::= { eponDeviceEventObjectEntry 10 } eponDevicePowerVoltageEventIndicationEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow PowerVoltageEventIndication event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 11 } eponDeviceGlobalEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Global Event indication of an EPON device. When the indication of the event input occurs the event is asserted. When the input is removed that event is de-asserted. When true the device has a Global Event asserted. When false the Global Event Indication is reset." ::= { eponDeviceEventObjectEntry 12 } eponDeviceGlobalEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow GlobalEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 13 } eponDeviceErroredSymbolPeriodEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Errored Symbol Period Event indication of the OAM alarm TLV indications as described in the [802.3ah] clause 57.5.3. When true the device has an Errored Symbol Period Event asserted. When false the Errored Symbol Period Event is reset." ::= { eponDeviceEventObjectEntry 14} eponDeviceErroredSymbolPeriodEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow ErroredSymbolPeriodEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 15 } eponDeviceErroredFrameEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Errored Frame Event indication of the OAM alarm TLV indications as described in the [802.3ah] clause 57.5.3. When true the device has an Errored Frame Event asserted. When false the Errored Frame Event is reset." ::= { eponDeviceEventObjectEntry 16 } eponDeviceErroredFrameEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow ErroredFrameEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 17 } eponDeviceErroredFramePeriodEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Errored Frame Period Event indication of the OAM alarm TLV indications as described in the [802.3ah] clause 57.5.3. When true the device has an Errored Frame Period Event asserted. When false the Errored Frame Period Event is reset." ::= { eponDeviceEventObjectEntry 18 } eponDeviceErroredFramePeriodEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow ErroredFramePeriodEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 19 } eponDeviceErroredFrameSecondsSummaryEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Errored Frame Seconds Summary Event indication of the OAM alarm TLV indications as described in the [802.3ah] clause 57.5.3. When true the device has an Errored Frame Seconds Summary Event asserted. When false the Errored Frame Seconds Summary Event is reset." ::= { eponDeviceEventObjectEntry 20 } eponDeviceErroredFrameSecondsSummaryEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow ErroredFrameSecondsSummaryEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 21 } eponDeviceOrganizationSpecificEventState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A read-only variable, which defines the state of the Organization Specific Event indication of the OAM alarm TLV indications as described in the [802.3ah] clause 57.5.3. When true the device has an Organization Specific Event asserted. When false the Organization Specific Event is reset." ::= { eponDeviceEventObjectEntry 22 } eponDeviceOrganizationSpecificEventEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to allow OrganizationSpecificEvent event to be used. When the value is true the event is sampled. When the value is false the event is not sampled. Writing can be done all the time." DEFVAL { false } ::= { eponDeviceEventObjectEntry 23 } eponDeviceEventControl OBJECT-TYPE SYNTAX INTEGER { none(1), resetLog(2), useDefaultReporting(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates and controls the resetting of the Event log. Setting this object to none(1) has no action resetLog(2) empties the event log. All data is deleted. Setting it to useDefaultReporting(3) returns all event priorities to their factory-default reporting. Reading this object always returns useDefaultReporting(3)." DEFVAL { 3 } ::= { eponDeviceEventObjectEntry 24 } -- Events Log Table eponDeviceEventsLogTable OBJECT-TYPE SYNTAX SEQUENCE OF EponDeviceEventsLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects provides a log of notification based on the event as pointed to by entries in those tables. The intent is a MAC level event log (set of events to when they happened). This attribute is relevant for an OLT and an ONU." ::= { eponDeviceEventObjects 2 } eponDeviceEventsLogEntry OBJECT-TYPE SYNTAX EponDeviceEventsLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A group of Events. Applications create and delete entries using eponDeviceEventsEntryStatus. When adding objects to a notification they are added in the lexical order of their index in this table." INDEX {eponDeviceEventsLogName, eponDeviceEventsLogIndex } ::= { eponDeviceEventsLogTable 1 } EponDeviceEventsLogEntry ::= SEQUENCE { eponDeviceEventsLogName SnmpAdminString, eponDeviceEventsLogIndex Unsigned32, eponDeviceEventsLogID OBJECT IDENTIFIER, eponDeviceEventsLogFirstTime DateAndTime, eponDeviceEventsLogLastTime DateAndTime, eponDeviceEventsLogCounts Counter32, eponDeviceEventsLogType INTEGER, eponDeviceEventsLogEntryStatus RowStatus } eponDeviceEventsLogName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A locally-unique, administratively assigned name for a group of Events." ::= { eponDeviceEventsLogEntry 1 } eponDeviceEventsLogIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer for the purpose of identifying individual Events within a eponDeviceEventsLogName group. Events within a group are placed in the notification in the numerical order of this index." ::= { eponDeviceEventsLogEntry 2 } eponDeviceEventsLogID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "The object identifier of a MIB module object to add to a Notification that results from the event. Writing can be done all the time." DEFVAL { zeroDotZero } ::= { eponDeviceEventsLogEntry 3 } eponDeviceEventsLogFirstTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time that an entry was created." ::= { eponDeviceEventsLogEntry 4 } eponDeviceEventsLogLastTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "If multiple events are reported via the same entry, the time that the last event for this entry occurred, otherwise this should have the same value as eponDeviceEventsLogFirstTime." ::= { eponDeviceEventsLogEntry 5 } eponDeviceEventsLogCounts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of consecutive event instances reported by this entry. This starts at 1 with the creation of this row and increments by 1 for each subsequent duplicate event." ::= { eponDeviceEventsLogEntry 6 } eponDeviceEventsLogType OBJECT-TYPE SYNTAX INTEGER { eponDeviceDyingGaspAlarmState (1), eponDeviceCriticalEventState (2), eponDeviceLocalLinkFaultAlarmState (3), eponDeviceTemperatureEventIndicationState (4), eponDevicePowerVoltageEventIndicationState (5), eponDeviceGlobalEventState (6), eponDeviceErroredSymbolPeriodEventState (7), eponDeviceErroredFrameEventState (8), eponDeviceErroredFramePeriodEventState (9), eponDeviceErroredFrameSecondsSummaryEventState (10), eponDeviceOrganizationSpecificEventState (11) } MAX-ACCESS read-only STATUS current DESCRIPTION "A list of types for Events. Events are ordered according to their significance where 1 is the highest severity. eponDeviceDyingGaspAlarmState(1) indicates a Dying Gasp Alarm State, eponDeviceCriticalEventState(2) indicates a Critical Event State, eponDeviceLocalLinkFaultAlarmState(3) indicates a Local Link Fault Alarm State, eponDeviceTemperatureEventIndicationState(4) indicates a Temperature Event Indication State, eponDevicePowerVoltageEventIndicationState(5) indicates a Power Voltage Event Indication State, eponDeviceGlobalEventState(6) indicates a Global Event State, eponDeviceErroredSymbolPeriodEventState(7) indicates an Errored Symbol Period Event State, eponDeviceErroredFrameEventState(8) indicates an Errored Frame Event State, eponDeviceErroredFramePeriodEventState(9) indicates an Errored Frame Period Event State, eponDeviceErroredFrameSecondsSummaryEventState(10) indicates an Errored Frame Seconds Summary Event State, eponDeviceOrganizationSpecificEventState(11) indicates an Organization Specific Event State. " ::= { eponDeviceEventsLogEntry 7 } eponDeviceEventsLogEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The control that allows creation and deletion of entries. Once made active an entry MAY not be modified except to delete it." ::= { eponDeviceEventsLogEntry 8 } -- Conformance Statements -- Conformance Groups eponDeviceGroups OBJECT IDENTIFIER ::={ eponDeviceConformance 1} eponDeviceGroupControl OBJECT-GROUP OBJECTS { eponDeviceObjectReset, eponDeviceObjectModes, eponDeviceObjectFecEnabled, eponDeviceObjectOamMode, eponDeviceObjectDeviceReadyMode, eponDeviceObjectPowerDown, eponDeviceObjectNumberOfLLIDs, eponDeviceObjectReportThreshold, eponDeviceRemoteMACAddressLLIDControl } STATUS current DESCRIPTION "A collection of objects of eponDevice control definition." ::= { eponDeviceGroups 1 } eponDeviceGroupRMadLTable OBJECT-GROUP OBJECTS { eponDeviceRMadlLLID, eponDeviceRMadlLogID, eponDeviceRMadlRemoteAddress, eponDeviceRMadlType, eponDeviceRMadlAction, eponDeviceRMadlEntryStatus } STATUS current DESCRIPTION "A collection of objects of eponDevice remote Mac address to LLID table." ::= { eponDeviceGroups 2 } eponDeviceGroupStat OBJECT-GROUP OBJECTS { eponDeviceStatTxFramesQueue0, eponDeviceStatTxFramesQueue1, eponDeviceStatTxFramesQueue2, eponDeviceStatTxFramesQueue3, eponDeviceStatTxFramesQueue4, eponDeviceStatTxFramesQueue5, eponDeviceStatTxFramesQueue6, eponDeviceStatTxFramesQueue7, eponDeviceStatRxFramesQueue0, eponDeviceStatRxFramesQueue1, eponDeviceStatRxFramesQueue2, eponDeviceStatRxFramesQueue3, eponDeviceStatRxFramesQueue4, eponDeviceStatRxFramesQueue5, eponDeviceStatRxFramesQueue6, eponDeviceStatRxFramesQueue7, eponDeviceStatDroppedFramesQueue0, eponDeviceStatDroppedFramesQueue1, eponDeviceStatDroppedFramesQueue2, eponDeviceStatDroppedFramesQueue3, eponDeviceStatDroppedFramesQueue4, eponDeviceStatDroppedFramesQueue5, eponDeviceStatDroppedFramesQueue6, eponDeviceStatDroppedFramesQueue7 } STATUS current DESCRIPTION "A collection of objects of EPON device Statistics" ::= { eponDeviceGroups 3 } eponDeviceGroupEvent OBJECT-GROUP OBJECTS { eponDeviceSampleMinimum, eponDeviceDyingGaspAlarmState, eponDeviceDyingGaspAlarmEnabled, eponDeviceCriticalEventState, eponDeviceCriticalEventEnabled, eponDeviceLocalLinkFaultAlarmState, eponDeviceLocalLinkFaultAlarmEnabled, eponDeviceTemperatureEventIndicationState, eponDeviceTemperatureEventIndicationEnabled, eponDevicePowerVoltageEventIndicationState, eponDevicePowerVoltageEventIndicationEnabled, eponDeviceGlobalEventState, eponDeviceGlobalEventEnabled, eponDeviceErroredSymbolPeriodEventState, eponDeviceErroredSymbolPeriodEventEnabled, eponDeviceErroredFrameEventState, eponDeviceErroredFrameEventEnabled, eponDeviceErroredFramePeriodEventState , eponDeviceErroredFramePeriodEventEnabled , eponDeviceErroredFrameSecondsSummaryEventState , eponDeviceErroredFrameSecondsSummaryEventEnabled, eponDeviceOrganizationSpecificEventState , eponDeviceOrganizationSpecificEventEnabled, eponDeviceEventControl } STATUS current DESCRIPTION "A collection of objects for EPON device Events" ::= { eponDeviceGroups 4 } eponDeviceGroupEventLog OBJECT-GROUP OBJECTS { eponDeviceEventsLogID, eponDeviceEventsLogFirstTime, eponDeviceEventsLogLastTime, eponDeviceEventsLogCounts, eponDeviceEventsLogType, eponDeviceEventsLogEntryStatus } STATUS current DESCRIPTION "A collection of objects for EPON device Events log" ::= { eponDeviceGroups 5 } -- Compliance eponDeviceCompliances OBJECT IDENTIFIER ::= {eponDeviceConformance 2} eponDeviceCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for EPON Devices." MODULE -- this module MANDATORY-GROUPS { eponDeviceGroupControl } GROUP eponDeviceGroupRMadLTable DESCRIPTION " This group is mandatory for all OLT EPON devices supporting LLID-MAC address table." GROUP eponDeviceGroupStat DESCRIPTION "This group is mandatory for all EPON devices supporting interfaces for Statistics collection." GROUP eponDeviceGroupEvent DESCRIPTION "This group is mandatory for all EPON devices supporting interfaces for event collection." GROUP eponDeviceGroupEventLog DESCRIPTION "This group is mandatory for all EPON devices supporting interfaces for event log collection." ::= { eponDeviceCompliances 1} END -- -- Copyright (C) The Internet Society (2004). This document is subject -- to the rights, licenses and restrictions contained in BCP 78, and -- except as set forth therein, the authors retain all their rights. -- Acknowledgment -- -- Funding for the RFC Editor function is currently provided by the -- Internet Society.