-- extracted from draft-ietf-hubmib-power-ethernet-mib-00.txt -- at Wed Jun 27 06:04:49 2001 PETH-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 , Gauge32,NOTIFICATION-TYPE FROM SNMPv2-SMI dot3 FROM EtherLike-MIB TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP ,NOTIFICATION-GROUP FROM SNMPv2-CONF; powerEthernetMIB MODULE-IDENTITY LAST-UPDATED "200106200000Z" -- June 20, 2001 ORGANIZATION "IETF Ethernet Interfaces and Hub MIB Working Group" CONTACT-INFO " Chair: Dan Romascanu Avaya Inc. Tel: +972-3-645-8414 Email: dromasca@avaya.com Editor: Avi Berger PowerDsine Inc. Tel: 972-9-7755100 Ext 307 Fax: 972-9-7755120 E-mail: avib@PowerDsine.com " DESCRIPTION "The MIB module for for managing Powered Devices (PD) or Power Source Equipment (PSE) working according to the IEEE 802.af Powere Ethernet (DTE Power via MDI) standard." ::= { dot3 20 } pethObjects OBJECT IDENTIFIER ::= { powerEthernetMIB 1 } pethNotifications OBJECT IDENTIFIER ::= { powerEthernetMIB 2 } pethConformance OBJECT IDENTIFIER ::= { powerEthernetMIB 3 } -- pethAgentControl MIB group defines the control objects for the power -- Ethernet Agent pethPsePortTable OBJECT-TYPE SYNTAX SEQUENCE OF PethPsePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects that display and control the power characteristics power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices." ::= { pethObjects 1 } pethPsePortEntry OBJECT-TYPE SYNTAX PethPsePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that display and control the power characteristics of a power Ethernet PSE port." INDEX { pethPsePortGroupIndex , pethPsePortIndex } ::= { pethPsePortTable 1 } PethPsePortEntry ::= SEQUENCE { pethPsePortGroupIndex INTEGER, pethPsePortIndex INTEGER, pethPsePortPowerEnable INTEGER, pethPsePortPowerIdPairsControl TruthValue, pethPsePortPowerIdPairs INTEGER, pethPsePortPowerDetectionStatus INTEGER, pethPsePortDetectionOperStatus INTEGER, pethPsePortPowerPriority INTEGER, pethPsePortDenyError INTEGER, pethPsePortStatus INTEGER, pethPsePortStatusClear INTEGER, pethPsePortType INTEGER, pethPsePortPowerClassifications INTEGER } pethPsePortGroupIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the group containing the port to which power Ethernet PSE is connected. Group means a box in the stack, or a module in a rack. For non-modular devices the value 1 is recommended." ::= { pethPsePortEntry 1 } pethPsePortIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the power Ethernet PSE port within group pethPseGroupIndex to which the power Ethernet PSE entry is connected." ::= { pethPsePortEntry 2 } pethPsePortPowerEnable OBJECT-TYPE SYNTAX INTEGER { auto(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables power supply on this port. Setting this object at a value auto(1) enables power and detection mechanism for this port. Setting this object at a value off(2) disables power and detection mechanism for this port." ::= { pethPsePortEntry 3 } pethPsePortPowerIdPairsControl OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the capability of controlling the power pairs functionality to switch pins for sourcing power." ::= { pethPsePortEntry 4 } pethPsePortPowerIdPairs OBJECT-TYPE SYNTAX INTEGER { signal(1), spare(2), both(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Describes or controls the pairs in use. If the value of pethPsePortPowerIdpairsControl is true, thisobject is writable. A value of signal(1) menas that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use. A value of both(3) means that both the signal and the spare pairs are in use." ::= { pethPsePortEntry 5 } pethPsePortPowerDetectionStatus OBJECT-TYPE SYNTAX INTEGER { auto(1), off(2), test(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the power detection mechanism of the port. Setting the value auto(1) enables the power detection mechanism of the port. Setting the value off(2) disables the power detection mechanism of the port. Setting the value test(3) puts the port in a test mode forcing continuous discovery without applying power regardless of whether PD detected." ::= { pethPsePortEntry 6 } pethPsePortDetectionOperStatus OBJECT-TYPE SYNTAX INTEGER { deliveringPower(1), off(2), searching(3), fault(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the operational status of the port detection. A value of deliveringPower(1) indicates that the port executed the detection algorithm, found a PD connection and is currently delivering power. A value of off(2) indicates that the port did not find a PD connection and is not in serching mode. A value of searching(3) indicates that the detection algorithm is in work, and did not detect a valid PD. No power is currently provided. A value of fault(4) indicates that a fault was detected on the port . " ::= { pethPsePortEntry 7 } pethPsePortPowerPriority OBJECT-TYPE SYNTAX INTEGER { critical(1), high(2), low(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used by a control mechanism that prevents over current situations by disconnecting first ports with lower power priority. Ports that connect devices critical to the operation of the network - like the E911 telephones ports - should be set to higher priority." ::= { pethPsePortEntry 8 } pethPsePortDenyError OBJECT-TYPE SYNTAX INTEGER { other(1), lowPriority(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object describes an error resulted from an action of the power management mechanism. The value lowPriority(2) indicates that the port was disabled by the power management system, in order to keep active higher priority ports." ::= { pethPsePortEntry 9 } pethPsePortStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), underCurrent(2), overCurrent(3), both(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes a current port status related to the power generation The value underCurrent(2) indicates that the port current is below the minimal value. The value overCurrent(3) indicates that the port current exceeds the maximal value. The value both(4) indicates that both underCurrent and overCurrent status happend from the lase Clear." ::= { pethPsePortEntry 10 } pethPsePortStatusClear OBJECT-TYPE SYNTAX INTEGER { clear(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this object to clear(1) clears the value of the pethPsePortStatus to none(1)." ::= { pethPsePortEntry 11 } pethPsePortType OBJECT-TYPE SYNTAX INTEGER { other(1), telephone(2), webcam(3), wireless(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "A manager will set the value of this variable to a value that indicates the type of the device that is connected to theport. This value can be the result of the mapping the address of the station connected to the port and of the value of the pethPdPortType of the respective PD port." ::= { pethPsePortEntry 12 } pethPsePortPowerClassifications OBJECT-TYPE SYNTAX INTEGER { class0(1), class1(2), class2(3), class3(4), class4(5), class5(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Classification is a way to tag different terminals on the power over LAN network according to their power consumption. Devices such as IP telephones, WLAN access points and others, will be classified according to their power requirements. Class Usage Maximum Power 0 Default 0.5 - 15.0 W 1 Optional 0.5 - 4.0 W 2 Optional 4.0 - 7.0 W 3 Optional 7.0 - 15.0 W 4 Optional Future Use 5 Optional Future Use " ::= { pethPsePortEntry 13 } -- PD Port table pethPdPortTable OBJECT-TYPE SYNTAX SEQUENCE OF PethPdPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects that display and control the power characteristics power Ethernet ports on a Powered Device(PD) device. This group will be implemented in managed powered and mid-span devices." ::= { pethObjects 2 } pethPdPortEntry OBJECT-TYPE SYNTAX PethPdPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that display and control the power characteristics of a Powered Device port." INDEX { pethPdPortIndex } ::= { pethPdPortTable 1 } PethPdPortEntry ::= SEQUENCE { pethPdPortIndex INTEGER, pethPdPortPowerPairs INTEGER, pethPdPortDetectionOperStatus INTEGER, pethPdPortType INTEGER } pethPdPortIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index value that uniquely identifies an interface to a PD device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex. The mapping between the ifIndex values and the numbering of the port on the device is an implementation issue." ::= { pethPdPortEntry 1 } pethPdPortPowerPairs OBJECT-TYPE SYNTAX INTEGER { signal(1), spare(2), both(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the pairs in use. A value of signal(1) menas that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use. A value of both(3) means that both the signal and the spare pairs are inuse." ::= { pethPdPortEntry 2 } pethPdPortDetectionOperStatus OBJECT-TYPE SYNTAX INTEGER { off(1), receivingPower(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the operational status of the port detection. The value off(1) means that the port does not receive power and the detection algorithm might still be operating. The value receivingPower(2) means that the port is receiving power. " ::= { pethPdPortEntry 3 } pethPdPortType OBJECT-TYPE SYNTAX INTEGER { other(1), telephone(2), webcam(3), wireless(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the device. A management application may read the value of this variable and use it for setting the corresponding value of pethPsePortType of the port that connects the device." ::= { pethPdPortEntry 4 } -- Main PSE Objects pethMainPseObjects OBJECT IDENTIFIER ::= { pethObjects 3 } pethMainPseTable OBJECT-TYPE SYNTAX SEQUENCE OF PethMainPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects that display and control the Main power on a PSE device." ::= { pethMainPseObjects 1 } pethMainPseEntry OBJECT-TYPE SYNTAX PethMainPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that display and control the Main power of a PSE." INDEX { pethMainPseGroupIndex } ::= { pethMainPseTable 1 } PethMainPseEntry ::= SEQUENCE { pethMainPseGroupIndex INTEGER, pethMainPsePower Integer32, pethMainPseOperStatus INTEGER, pethMainPseConsumptionPower Gauge32, pethMainPseBackupPresent INTEGER, pethMainPseBackupActivated INTEGER, pethMainPseUsageThreshold INTEGER } pethMainPseGroupIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means box in the stack, module in a rack. It is recommended that the value 1 be used for non-modular devices " ::= { pethMainPseEntry 1 } pethMainPsePower OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The nominal power of the PSE expressed in Watts." ::= { pethMainPseEntry 2 } pethMainPseOperStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), faulty(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status of the main PSE." ::= { pethMainPseEntry 3 } pethMainPseConsumptionPower OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Measured usage power expressed in Watts." ::= { pethMainPseEntry 4 } pethMainPseBackupPresent OBJECT-TYPE SYNTAX INTEGER { present(1), notPresent(2), faulty(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value reflects the presence and status of a backup PSE ." ::= { pethMainPseEntry 5 } pethMainPseBackupActivated OBJECT-TYPE SYNTAX INTEGER { activated(1), notActivated(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable reflects the activation status of the backup PSE" ::= { pethMainPseEntry 6 } pethMainPseUsageThreshold OBJECT-TYPE SYNTAX INTEGER (1..99) MAX-ACCESS read-write STATUS current DESCRIPTION "The usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded." ::= { pethMainPseEntry 7 } -- Traps Control Objects pethTrapsControl OBJECT IDENTIFIER ::= { pethObjects 4 } pethTrapsControlTable OBJECT-TYPE SYNTAX SEQUENCE OF PethTrapsControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects that display and control the Main power on a PSE device." ::= { pethTrapsControl 1 } pethTrapsControlEntry OBJECT-TYPE SYNTAX PethTrapsControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that control the Trap events." INDEX { pethTrapsControlGroupIndex } ::= { pethTrapsControlTable 1 } PethTrapsControlEntry ::= SEQUENCE { pethTrapsControlGroupIndex INTEGER, pethTrapsControlEnable INTEGER } pethTrapsControlGroupIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the group. Group means box in the stack, or module in a rack. It is recommended that the value 1 is used for non-modular devices." ::= { pethTrapsControlEntry 1 } pethTrapsControlEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable Traps from Agent" ::= { pethTrapsControlEntry 2 } -- -- Notifications Section -- -- pethPsePortOnOffTrap NOTIFICATION-TYPE OBJECTS { pethPsePortGroupIndex,pethPsePortIndex,pethPsePortDetectionOperStatus } STATUS current DESCRIPTION " This trap indicate if Pse Port is delivering or not power to the PD." ::= { pethNotifications 1 } pethPsePortDenyTrap NOTIFICATION-TYPE OBJECTS { pethPsePortGroupIndex,pethPsePortIndex,pethPsePortDenyError } STATUS current DESCRIPTION " This trap indicate Port Deny service." ::= { pethNotifications 2 } pethPsePortStatusTrap NOTIFICATION-TYPE OBJECTS { pethPsePortGroupIndex,pethPsePortIndex,pethPsePortStatus } STATUS current DESCRIPTION " This trap indicate Port Change Status." ::= { pethNotifications 3 } pethMainPseBackUpActivatedTrap NOTIFICATION-TYPE OBJECTS { pethPsePortGroupIndex,pethMainPseBackupActivated } STATUS current DESCRIPTION " This trap indicates that BackUp PSE is Activated ." ::= { pethNotifications 4 } pethMainPowerUsageTrap NOTIFICATION-TYPE OBJECTS { pethPsePortGroupIndex } STATUS current DESCRIPTION " This trap indicate PSE Threshold usage indication ." ::= { pethNotifications 5 } -- -- Conformance Section -- pethCompliances OBJECT IDENTIFIER ::= { pethConformance 1 } pethGroups OBJECT IDENTIFIER ::= { pethConformance 2 } pethCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Describes the requirements for conformance to the Power Ethernet MIB." MODULE -- this module GROUP pethPsePortGroup DESCRIPTION "The pethPsePortGroup is mandatory for systems which implement PSE ports." GROUP pethPdPortGroup DESCRIPTION "The pethPdPortGroup is mandatory for systems which implement PD Ports." GROUP pethMainPseGroup DESCRIPTION "The pethMainPseGroup is mandatory for systems which implement main power supply within a PSE Device." GROUP pethTrapsControlGroup DESCRIPTION "The pethTrapsControlGroup is mandatory for systems which implement PSE ports." ::= { pethCompliances 1 } pethPsePortGroup OBJECT-GROUP OBJECTS { pethPsePortPowerEnable, pethPsePortPowerIdPairsControl, pethPsePortPowerIdPairs, pethPsePortPowerDetectionStatus, pethPsePortDetectionOperStatus, pethPsePortPowerPriority, pethPsePortDenyError, pethPsePortStatus, pethPsePortStatusClear, pethPsePortType, pethPsePortPowerClassifications } STATUS current DESCRIPTION "PSE Port Objects." ::= { pethGroups 1 } pethPdPortGroup OBJECT-GROUP OBJECTS { pethPdPortPowerPairs, pethPdPortDetectionOperStatus, pethPdPortType } STATUS current DESCRIPTION "PD Port Objects." ::= { pethGroups 2 } pethMainPseGroup OBJECT-GROUP OBJECTS { pethMainPsePower, pethMainPseOperStatus, pethMainPseConsumptionPower, pethMainPseBackupPresent, pethMainPseBackupActivated, pethMainPseUsageThreshold } STATUS current DESCRIPTION "Main PSE Objects. " ::= { pethGroups 3 } pethTrapsControlGroup OBJECT-GROUP OBJECTS { pethTrapsControlEnable } STATUS current DESCRIPTION "Trap Control Objects. " ::= { pethGroups 4 } END -- -- This document and translations of it may be copied and furnished to -- others, and derivative works that comment on or otherwise explain it -- or assist in its implementation may be prepared, copied, published -- and distributed, in whole or in part, without restriction of any -- kind, provided that the above copyright notice and this paragraph are -- included on all such copies and derivative works. However, this -- document itself may not be modified in any way, such as by removing -- the copyright notice or references to the Internet Society or other -- Internet organizations, except as needed for the purpose of -- developing Internet standards in which case the procedures for -- copyrights defined in the Internet Standards process must be -- followed, or as required to translate it into languages other than -- English. -- The limited permissions granted above are perpetual and will not be -- revoked by the Internet Society or its successors or assigns. -- -- This document and the information contained herein is provided on an -- "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING -- TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING -- BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION -- HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF -- MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.