-- extracted from draft-ietf-ipcdn-pktc-eventmess-11.txt -- at Fri Oct 26 06:11:33 2007 PKTC-IETF-EVENT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, NOTIFICATION-TYPE, mib-2 FROM SNMPv2-SMI TruthValue, DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC SnmpAdminString FROM SNMP-FRAMEWORK-MIB OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP FROM SNMPv2-CONF ifPhysAddress FROM IF-MIB InetAddressType, InetAddress, InetPortNumber FROM INET-ADDRESS-MIB snmpTargetBasicGroup, snmpTargetResponseGroup FROM SNMP-TARGET-MIB snmpNotifyGroup, snmpNotifyFilterGroup FROM SNMP-NOTIFICATION-MIB SyslogSeverity, SyslogFacility FROM SYSLOG-TC-MIB; pktcIetfEventMib MODULE-IDENTITY LAST-UPDATED "200709300000Z" -- September 30, 2007 ORGANIZATION "IETF IP over Cable Data Network Working Group" CONTACT-INFO "Sumanth Channabasappa Cable Television Laboratories, Inc. 858 Coal Creek Circle, Louisville, CO 80027, USA +1 303-661-3307 Sumanth@cablelabs.com Wim De Ketelaere tComLabs Gildestraat 8 9000 Gent, Belgium +32 9 269 22 90 deketelaere@tComLabs.com Eugene Nechamkin Broadcom Corporation 200 - 13711 International Place Richmond, BC, V6V 2Z8, Canada +1 604 233 8500 enechamkin@broadcom.com IETF IPCDN Working Group General Discussion: ipcdn@ietf.org Subscribe: http://www.ietf.org/mailman/listinfo/ipcdn Archive: ftp://ftp.ietf.org/ietf-mail-archive/ipcdn Co-Chair: Jean-Francois Mule, jf.mule@cablelabs.com Co-Chair: Richard Woundy, Richard_Woundy@cable.comcast.com" DESCRIPTION "This MIB module specifies the basic management objects for managing events generated by the Multimedia Terminal Adapter devices compliant with the PacketCable and IPCablecom requirements. Copyright (C) The IETF Trust (2007). This version of this MIB module is part of RFC nnnn; see the RFC itself for full legal notices." -- RFC Ed: replace nnnn with actual RFC number and remove this note. REVISION "200709300000Z" -- September 30, 2007 DESCRIPTION "Initial version, published as RFC yyyy." -- RFC Ed: replace yyyy with actual RFC number and remove this note ::= { mib-2 XXX } -- RFC Ed: replace XXX with IANA-assigned number and remove this -- note SyslogSeverityMask ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention represents a bit mask representing the severity of the syslog events that can be generated. It corresponds to the various severity levels associated with syslog messages, as specified in The syslog Protocol, [RFCAAA]. emergency(0) - A condition that makes the system unusable. alert(1) - A service-affecting condition for which immediate action must be taken. critical(2) - A service-affecting critical condition. error(3) - An error condition. warning(4) - A warning condition. notice(5) - A normal but significant condition. info(6) - An informational message. debug(7) - A debug message." SYNTAX BITS { emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), info(6), debug(7) } -- -- pktcEventNotifications OBJECT IDENTIFIER ::= { pktcIetfEventMib 0 } pktcEventMibObjects OBJECT IDENTIFIER ::= { pktcIetfEventMib 1 } pktcEventConformance OBJECT IDENTIFIER ::= { pktcIetfEventMib 2 } -- -- pktcEventControl OBJECT IDENTIFIER ::= { pktcEventMibObjects 1 } pktcEventThrottle OBJECT IDENTIFIER ::= { pktcEventMibObjects 2 } pktcEventStatus OBJECT IDENTIFIER ::= { pktcEventMibObjects 3 } pktcEvents OBJECT IDENTIFIER ::= { pktcEventMibObjects 4 } pktcEventLog OBJECT IDENTIFIER ::= { pktcEventMibObjects 5 } --- -- Event Reporting control objects --- pktcEventReset OBJECT-TYPE SYNTAX BITS { resetEvLogTable(0), resetEvDescrTable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object allows a management station to clear the local log of generated events, reset the management event descriptions, or both. MTAs generate management events. These events are stored in the MIB table 'pktcEventLogTable'. If a management station needs to clear all the current entries (e.g., after a troubleshooting operation is complete), it can do so by setting the resetEvLogTable(0) bit to a value of '1'. The MTA is pre-configured with the events that it can generate. This is stored in the MIB table 'pktcEventTable'. This table also contains the descriptions associated with these events. These descriptions can be modified by a management station. However, if the management station wishes to reset the descriptions, to factory defaults, it can do so by setting the resetEvDescrTable(1) bit to a value of '1'. The MTA actions are summarized below: Bit resetEvLogTable(0) set to a value of '1' - delete all entries in pktcEventLogTable; - reset the value of pktcEventLogIndex to '0'. Bit resetEvDescrTable(1) set to a value of '1' - reset the pktcEventTable to the factory default values. Bits resetEvLogTable(0) and resetEvDescrTable(1) set to a value of '1' - perform the above actions as though they were performed individually (in any order). Setting a reset bit to a value of '0' MUST NOT result in any action. The MTA MUST perform the above actions regardless of persistence (i.e. storage in non-volatile memory). The MTA MUST always return a value of '00' when this MIB object is read. It is to be noted that the presence of multiple SNMP managers managing the same MTA can result in multi-manager contentions for this MIB object that are not addressed." ::= { pktcEventControl 1 } --- -- syslog-specific MIB objects --- pktcEventSyslog OBJECT IDENTIFIER ::= { pktcEventControl 2 } pktcEventSyslogCapabilities OBJECT-TYPE SYNTAX BITS { formatBSDSyslog(0), formatSyslogProtocol(1), transportUDP(2), transportTLS(3), transportBEEP(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object contains the MTA capabilities for supporting the Syslog protocol, specifically the message formats and the transport protocols. The BSD syslog message format is specified in [RFC3164] (formatBSDSyslog), and the IETF syslog protocol is specified in [RFCAAA] (formatSyslogProtocol). The MTA MUST set the appropriate protocol and transport bits, based on implementation." REFERENCE "The BSD syslog Protocol, [RFC3164]; The syslog Protocol, [RFCAAA]; Transmission of syslog messages over UDP, [RFCBBB]; TLS Transport Mapping for Syslog, [RFCCCC]." ::= { pktcEventSyslog 1 } pktcEventSyslogAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object defines the Internet address type of the syslog server specified by the MIB object 'pktcEventSyslogAddress' ." REFERENCE "PacketCable MTA Device Provisioning Specification, [PKT-SP-PROV]." DEFVAL { ipv4 } ::= { pktcEventSyslog 2 } pktcEventSyslogAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object contains the IP address of the syslog server to which the MTA can transmit a syslog message upon the generation of a management event. The type of address this object represents is defined by the MIB object pktDevEventSyslogAddressType. The use of FQDNs is syntactically allowed, but not recommended since a failure to resolve them in a timely manner may leave the device without access to the syslog service during critical network events. The MTA SHOULD NOT attempt to route to a non-routable syslog IP address. The format of the syslog message is specified by the MIB object 'pktcEventSyslogMessageFormat'." REFERENCE "PacketCable MTA Device Provisioning Specification, [PKT-SP-PROV]; PacketCable Management Event Mechanism Specification, [PKT-SP-MEM1.5];" DEFVAL { "0.0.0.0" } ::= { pktcEventSyslog 3 } pktcEventSyslogMessageFormat OBJECT-TYPE SYNTAX INTEGER { formatBSDSyslog(1), -- The BSD syslog Protocol formatSyslogProtocol(2) -- The syslog Protocol } MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object contains the syslog message format to be used for transmitting syslog messages to the server contained in the MIB object 'pktcEventSyslogServer'." REFERENCE "The BSD syslog Protocol, [RFC3164]; The syslog Protocol, [RFCAAA]." DEFVAL { formatBSDSyslog } ::= { pktcEventSyslog 4 } pktcEventSyslogTransport OBJECT-TYPE SYNTAX INTEGER { udp(1),-- Transmission of syslog messages over UDP tls(2),-- TLS Transport Mapping for Syslog beep(3)-- BEEP Transport Mapping for Syslog } MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object specifies the transport to be used to transmit syslog messages to the syslog server contained in the MIB object 'pktcEventSyslogAddress'. If the MTA does not support the transport specified in a SET operation, then the MTA MUST return an appropriate error response, such as 'inconsistentValue'." REFERENCE "Transmission of syslog messages over UDP, [RFCBBB]; TLS Transport Mapping for Syslog, [RFCCCC]." DEFVAL {udp} ::= { pktcEventSyslog 5 } pktcEventSyslogPort OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object contains the port number of the syslog Server to which the syslog messages are to be transmitted." REFERENCE "Transmission of syslog messages over UDP, [RFCBBB]; TLS Transport Mapping for Syslog, [RFCCCC]." DEFVAL { 514 } ::= { pktcEventSyslog 6 } --- -- Event classes --- pktcEventClassTable OBJECT-TYPE SYNTAX SEQUENCE OF PktcEventClassEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This MIB table allows for management events that can be generated by an MTA to be classified into categories, or 'event classes'. For example, all the configuration related events can be associated with an event class titled 'configuration'. Such as a classification allows for a management station to affect changes on a common group of events, at once. Two operations are specified on an event class: enabling or disabling of all the events in an event class, and selective enabling or disabling based on the severity level." ::= { pktcEventControl 3 } pktcEventClassEntry OBJECT-TYPE SYNTAX PktcEventClassEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table specifies an event class, a grouping of events, as identified by the MTA manufacturer. Any event associated with an event class in this table MUST be specified in the pktcEventTable. The MTA MUST create one entry (index=100) for the event class titled 'generic'. This event class MUST contain all the events that are not contained in any other vendor specified event class. An event can belong to multiple event classes. In such a case, the event class with the lowest index takes precedence. The event table (pktcEventTable) provides the event class that affects the event. Whenever an event is generated, the MTA MUST verify the corresponding event class entries to take any specified actions. Entries in this table persist across resets and reboots." INDEX { pktcEventClassIndex } ::= { pktcEventClassTable 1 } PktcEventClassEntry::= SEQUENCE { pktcEventClassIndex Unsigned32, pktcEventClassName SnmpAdminString, pktcEventClassStatus TruthValue, pktcEventClassSeverity SyslogSeverityMask } pktcEventClassIndex OBJECT-TYPE SYNTAX Unsigned32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This MIB object is an index into the event class table. It is a locally-meaningful value, and needs to remain consistent across MTA resets and reboots." ::= { pktcEventClassEntry 1 } pktcEventClassName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (1..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object contains the name of the event class. Vendors MAY define different event classes (e.g. DHCP, SNMP, DEBUG) to group together management events of a particular category. Event class names need to take into consideration the SnmpAdminString definition requirements such as the use of control code sequence CR LF to represent a newline." ::= { pktcEventClassEntry 2 } pktcEventClassStatus OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object indicates if events belonging to the corresponding event class are enabled or disabled, for event reporting. Setting this object to a value of 'true' enables reporting of all the events in the event class. When enabled, the means of reporting events is specified by the MIB object 'pktcEventReporting'. Setting this object to a value of 'false' disables any event reporting, irrespective of the value of the MIB object 'pktcEventReporting' for a specific event. The default value of this MIB object is vendor specific. However, the vendor SHOULD enable all event categories defined by PacketCable or IPCableCom, by default." ::= { pktcEventClassEntry 3 } pktcEventClassSeverity OBJECT-TYPE SYNTAX SyslogSeverityMask MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object defines the severity level of events belonging to a specific event class that are enabled for event reporting. This MIB object has no effect on the event reporting unless the MIB object 'pktcEventClassStatus' is set to a value of 'true' (enabled), for the corresponding event class. Setting a bit within the mask to a value of '1' implies that events corresponding to that severity level MUST be reported as defined by the corresponding value of 'pktcEventReporting' for events in the event class. Setting a bit to a value of '0' implies that events corresponding to that level MUST NOT be reported, irrespective of the corresponding value of 'pktcEventReporting' for events in the event class. It is recommended that the bits corresponding to emergency(0), alert(1), critical(2) and error(3) be set to a value of '1' to ensure reporting of events requiring immediate attention." REFERENCE "The syslog Protocol, [RFCAAA]; Syslog Management Information Base, [RFCABC]." ::= { pktcEventClassEntry 4 } --- -- Event throttling control --- pktcEventThrottleAdminStatus OBJECT-TYPE SYNTAX INTEGER { unconstrained(1), maintainBelowThreshold(2), stopAtThreshold(3), inhibited(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object controls the throttling of the transmitted messages upon generation of an event (SNMP/syslog). It does not affect local logging of events. A value of unconstrained(1) causes event messages to be transmitted without regard to the threshold settings. A value of maintainBelowThreshold(2) causes event messages to be suppressed if the number of transmissions would otherwise exceed the threshold specified by pktcEventThrottleThreshold over the interval specified by pktcEventThrottleInterval. A value of stopAtThreshold(3) causes event message transmission to cease once the threshold specified by pktcEventThrottleThreshold (over the interval specified by pktcEventThrottleInterval) is reached. Event generation is resumed when the value of this MIB object is modified by a Management Station, or the device resets or reboots. A value of inhibited(4) causes all event message transmission to be suppressed. An event causing both an SNMP and a syslog message is still treated as a single event. Refer to MIB objects pktcEventThrottleThreshold and pktcEventThrottleInterval for information on throttling." DEFVAL { unconstrained } ::= { pktcEventThrottle 1 } pktcEventThrottleThreshold OBJECT-TYPE SYNTAX Unsigned32(0..1024) MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object contains the number of events per pktcEventThrottleInterval to be transmitted before throttling. An event resulting in multiple actions (e.g., SNMP and syslog) is still treated as a single event." DEFVAL { 2 } ::= { pktcEventThrottle 2 } pktcEventThrottleInterval OBJECT-TYPE SYNTAX Unsigned32(0..604800) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object contains the interval over which the throttle threshold applies." DEFVAL { 1 } ::= { pktcEventThrottle 3 } --- -- Reporting of transmission status --- pktcEventTransmissionStatus OBJECT-TYPE SYNTAX BITS { syslogThrottled(0), snmpThrottled(1), validsyslogServerAbsent(2), validSnmpManagerAbsent(3), syslogTransmitError(4), snmpTransmitError(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object reflects the status of the event transmissions. If a bit corresponding to a state is set to a value of: '1', it indicates that the state is true '0', it indicates that the state is false 'Event throttling' is based on thresholds and the current setting of pktcEventThrottleAdminStatus. 'Server/Manager' indicators is based on the availability of valid syslog server/SNMP managers. 'Transmit Errors' is only used in cases where the MTA can identify such scenarios. It is to be noted that not all the conditions that are indicated by this MIB object are detectable by all devices, and when detected may not be accurate. It is meant to provide a report of the status as determined by the device during event transmissions." ::= { pktcEventStatus 1 } --- -- Description of events --- pktcEventTable OBJECT-TYPE SYNTAX SEQUENCE OF PktcEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This MIB table contains all possible management events that can be generated by the device. This includes both PacketCable and IPCableCom defined, and vendor-specific events." ::= { pktcEvents 1 } pktcEventEntry OBJECT-TYPE SYNTAX PktcEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created for each event the MTA implementing this MIB is capable of reporting. Entries in this table are persisted across resets and reboots." INDEX { pktcEventOrg, pktcEventId } ::= { pktcEventTable 1 } PktcEventEntry::= SEQUENCE { pktcEventOrg Unsigned32, pktcEventId Unsigned32, pktcEventFacility INTEGER, pktcEventSeverityLevel SyslogSeverity, pktcEventReporting BITS, pktcEventText SnmpAdminString, pktcEventClass SnmpAdminString } pktcEventOrg OBJECT-TYPE SYNTAX Unsigned32(1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This MIB object provides the IANA enterprise number of the Organization defining the event. Thus, all PacketCable or IPCableCom defined events will contain the PacketCable or IPCableCom IANA enterprise number and for vendor-specific events it will contain the IANA enterprise number of the defining organization." REFERENCE "IANA Enterprise ID assignment, [IANA-ENTERPRISE]." ::= { pktcEventEntry 1 } pktcEventId OBJECT-TYPE SYNTAX Unsigned32(1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This MIB object contains the event identifier for the corresponding event." REFERENCE "PacketCable Management Event Mechanism Specification, [PKT-SP-MEM1.5]; PacketCable MTA Device Provisioning Specification, [PKT-SP-PROV]." ::= { pktcEventEntry 2 } pktcEventFacility OBJECT-TYPE SYNTAX SyslogFacility MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object contains the facility for the event. For PacketCable, IPCableCom or ETSI events this MUST be set to a value of local0(16)." REFERENCE "The syslog Protocol, [RFCAAA]; Textual Conventions for Syslog Management, [RFCDDD]." ::= { pktcEventEntry 3 } pktcEventSeverityLevel OBJECT-TYPE SYNTAX SyslogSeverity MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object contains the severity level that is applicable to the specified event." REFERENCE "The syslog Protocol, [RFCAAA]; Textual Conventions for Syslog Management, [RFCDDD]." ::= { pktcEventEntry 4 } pktcEventReporting OBJECT-TYPE SYNTAX BITS { local(0), syslog(1), snmpTrap(2), snmpInform(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object defines the action to be taken on occurrence of this event. Bit local(0) refers to local logging of events, bit sylog(1) refers to the transmission of events using syslog, bit snmpTrap(2) refers to the transmission of events using SNMP Traps (SNMPv2-Trap-PDU) and bit snmpInform(3)refers to the transmission of events using SNMP INFORMs. Setting a bit to a value of '1' indicates that the corresponding action will be taken upon occurrence of this event. If none of the bits are set then no action is taken upon occurrence of the event. The success of transmission using syslog and SNMP depends on the MTA configuration. For example, a valid syslog server address is required for syslog message transmission. Specification of a management event does not necessarily include the actions to be taken upon its generation, i.e., it does not need to specify if a generated event needs to be transmitted via SNMP, syslog or stored locally. Thus, certain default values are specified, based on the event's severity level specified by the MIB object 'pktcEventSeverityLevel', as follows: - If the severity level of an event is emergency(0), alert(1), critical(2) or error(3), set the bits for local(0), syslog(1) and snmpInform(3) to a value of '1', and the remaining bits to a value of '0'. - For an event with any other severity level set the bits for local(0) and syslog(1) to a value of of '1', and the rest of the bits to a value of '0'. " ::= { pktcEventEntry 5 } pktcEventText OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB object provides a human-readable description of the event. Descriptions need to take into consideration the SnmpAdminString definition requirements such as the use of control code sequence CR LF to represent a newline." ::= { pktcEventEntry 6 } pktcEventClass OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object represents the event class that affects the event. If an event is associated with only one event class, then its name (pktcEventClassName) is reported. If an event is associated with more than one event class, then the name of the event class with the lowest index in the event class table (pktcEventClassTable) is reported. See the MIB table 'pktcEventClassTable' for a description of event classes and usage. Descriptions need to take into consideration the SnmpAdminString definition requirements such as the use of control code sequence CR LF to represent a newline." ::= { pktcEventEntry 7 } --- -- Log of generated events --- pktcEventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF PktcEventLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This MIB table contains a log of the events generated by the MTA. A description of all the events that can be generated by the device can be obtained from the MIB table 'pktcEventTable'. An MTA is not required to persist the contents of this table across resets. In such cases, the log of events is preserved across resets and reboots. If not, the log of events is lost across resets and reboots." ::= { pktcEventLog 1 } pktcEventLogEntry OBJECT-TYPE SYNTAX PktcEventLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table describes an event that has occurred, indexed in the chronological order of generation. The details of the event are borrowed from the parameters associated with the corresponding event entry in 'pktcEventTable', at the time of the event generation. While all entries created as such can be cleared using the MIB object pktcEventReset, the Event entries themselves cannot be individually deleted." INDEX { pktcEventLogIndex } ::= { pktcEventLogTable 1 } PktcEventLogEntry ::= SEQUENCE { pktcEventLogIndex Unsigned32, pktcEventLogTime DateAndTime, pktcEventLogOrganization Unsigned32, pktcEventLogIdentifier Unsigned32, pktcEventLogText SnmpAdminString, pktcEventLogEndpointName SnmpAdminString, pktcEventLogType BITS, pktcEventLogTargetInfo SnmpAdminString, pktcEventLogCorrelationId Unsigned32, pktcEventLogAdditionalInfo SnmpAdminString } pktcEventLogIndex OBJECT-TYPE SYNTAX Unsigned32(1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This MIB object provides relative ordering of the objects in the event log. If the MTA implements non-volatile storage, then this object will always increase except when it reaches the value of 2^31. If the MTA does not implement non-volatile storage, then this object will always increase except when it reaches the value of 2^31 or the MTA is reset. When the value reaches 2^31 or is reset, newer events will be stored starting with an index value of '1' (cyclic rotation)." ::= { pktcEventLogEntry 1 } pktcEventLogTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object provides a human-readable description of the time at which the event occurred. The time used SHOULD comply with the specified syslog format (see pktcEventSyslogMessageFormat)." REFERENCE "The BSD syslog Protocol, [RFC3164]; The syslog Protocol, [RFCAAA]." ::= { pktcEventLogEntry 2 } pktcEventLogOrganization OBJECT-TYPE SYNTAX Unsigned32(1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object provides the IANA enterprise number of the Organization defining the event. Thus, all PacketCable or IPCableCom defined events will contain the CableLabs or IPCableCom IANA enterprise number and for vendor-specific events it will contain the IANA enterprise number of the defining organization." ::= { pktcEventLogEntry 3 } pktcEventLogIdentifier OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object contains the event identifier for the corresponding event." ::= { pktcEventLogEntry 4 } pktcEventLogText OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object contains the contents of the MIB object 'pktcEventText', corresponding to the event, at the moment of generation." ::= { pktcEventLogEntry 5 } pktcEventLogEndpointName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object provides the endpoint identifier followed by the PacketCable MTA's Fully Qualified Domain Name (FQDN) and the IP Address (IP) of the PacketCable MTA device. This will be denoted as follows: aaln/n:/, where 'n' is the Endpoint number. or / if it is not specific to an endpoint. Endpoint identifiers need to observe the SnmpAdminString definition requirements." ::= { pktcEventLogEntry 6 } pktcEventLogType OBJECT-TYPE SYNTAX BITS { local(0), syslog(1), trap(2), inform(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object contains the type of actions taken by the MTA, when the event indicated by the MIB object 'pktcEventLogIdentifier' occurred. A bit with a value of '1' indicates the corresponding action was taken. Setting it to a value of '0' indicates that the corresponding action was not taken. An event may trigger one or more actions (e.g.: syslog and SNMP), or result only in a local log. An action may also be prevented due to throttling in which case it is not reported by this MIB object." ::= { pktcEventLogEntry 7 } pktcEventLogTargetInfo OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object contains a comma separated list of the actions taken for external notifications, along with the target IP address for the generated events. Locally stored events MUST NOT be recorded in this MIB object. The syntax is as: ,, Where is to be denoted as follows: For syslog events: syslog/ For SNMP traps: snmpTrap/ For SNMP INFORMS: snmpInform/ If there are multiple targets for the same type (SNMP Traps sent to multiple IP addresses) or if there are multiple message types sent to the same IP (syslog and SNMP sent to the same IP address) they need to be reported individually. It is to be noted that this MIB object may not be able to store all the data in some cases (e.g., multiple IPv6 addresses) in which case some actions may not be reported. In such cases, the MTA MUST present a value of '...' at the end of the value. Values contained by this MIB object need to observe the SnmpAdminString definition requirements." ::= { pktcEventLogEntry 8 } pktcEventLogCorrelationId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object contains the correlation ID generated by the MTA during the initiation of the last provisioning flow, within or following which the event occurred. Although a Correlation-ID, once generated after MTA reset, does not change until next MTA reset, the value of this object will differ for the events preserved across MTA resets in case of a persistent pktcEventLogTable. For more information on the generation of correlation ids, refer to the corresponding PacketCable/IPCableCom Device Provisioning specifications." REFERENCE "PacketCable MTA Device Provisioning Specification, [PKT-SP-PROV]." ::= { pktcEventLogEntry 9 } pktcEventLogAdditionalInfo OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object contains additional, useful information in relation to the corresponding event that an MTA might wish to report such as parameterized data or debugging information. The format is vendor-specific. If MTA cannot provide any additional information for the particular event generated, it MUST populate this MIB object with a zero-length OCTET-STRING. Vendors providing this information need to observe the SnmpAdminString definition requirements such as the use of control code sequence CR LF for newline." ::= { pktcEventLogEntry 10 } --- -- Notifications --- pktcEventNotification NOTIFICATION-TYPE OBJECTS { pktcEventLogTime, pktcEventLogOrganization, pktcEventLogIdentifier, pktcEventLogEndpointName, pktcEventLogCorrelationId, ifPhysAddress } STATUS current DESCRIPTION "This Notification MIB object contains the contents for event reporting. It contains the event log time, the organization ID, the event identifier, the endpoint identifier, the correlation id, and the MTA's MAC address." ::= { pktcEventNotifications 1 } --- -- Conformance/Compliance --- pktcEventCompliances OBJECT IDENTIFIER ::= { pktcEventConformance 1 } pktcEventGroups OBJECT IDENTIFIER ::= { pktcEventConformance 2 } pktcEventBasicCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for devices that implement Event reporting feature." MODULE --pktcIetfEventMib MANDATORY-GROUPS { pktcEventGroup, pktcEventNotificationGroup } MODULE SNMP-TARGET-MIB MANDATORY-GROUPS { snmpTargetBasicGroup, snmpTargetResponseGroup } MODULE SNMP-NOTIFICATION-MIB MANDATORY-GROUPS { snmpNotifyGroup, snmpNotifyFilterGroup } ::= { pktcEventCompliances 3 } pktcEventGroup OBJECT-GROUP OBJECTS { pktcEventReset, pktcEventSyslogCapabilities, pktcEventSyslogAddressType, pktcEventSyslogAddress, pktcEventSyslogTransport, pktcEventSyslogPort, pktcEventSyslogMessageFormat, pktcEventThrottleAdminStatus, pktcEventThrottleThreshold, pktcEventThrottleInterval, pktcEventTransmissionStatus, pktcEventFacility, pktcEventSeverityLevel, pktcEventReporting, pktcEventText, pktcEventLogTime, pktcEventLogOrganization, pktcEventLogIdentifier, pktcEventLogText, pktcEventLogEndpointName, pktcEventLogType, pktcEventLogTargetInfo, pktcEventLogCorrelationId, pktcEventLogAdditionalInfo, pktcEventClass, pktcEventClassName, pktcEventClassStatus, pktcEventClassSeverity } STATUS current DESCRIPTION "Group of MIB objects for PacketCable Management Event MIB." ::= { pktcEventGroups 1 } pktcEventNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { pktcEventNotification } STATUS current DESCRIPTION "Group of MIB objects for notifications related to change in status of the MTA Device." ::= { pktcEventGroups 2 } END -- -- Copyright (C) The IETF Trust (2007). -- -- This document is subject to the rights, licenses and restrictions -- contained in BCP 78, and except as set forth therein, the authors -- retain all their rights. -- -- This document and the information contained herein are provided on -- an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE -- REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY, THE -- IETF TRUST AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL -- WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY -- WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE -- ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS -- FOR A PARTICULAR PURPOSE. -- -- Intellectual Property -- -- The IETF takes no position regarding the validity or scope of any -- Intellectual Property Rights or other rights that might be claimed -- to pertain to the implementation or use of the technology described -- in this document or the extent to which any license under such -- rights might or might not be available; nor does it represent that -- it has made any independent effort to identify any such rights. -- Information on the procedures with respect to rights in RFC -- documents can be found in BCP 78 and BCP 79. -- -- Copies of IPR disclosures made to the IETF Secretariat and any -- assurances of licenses to be made available, or the result of an -- attempt made to obtain a general license or permission for the use -- of such proprietary rights by implementers or users of this -- specification can be obtained from the IETF on-line IPR repository -- at http://www.ietf.org/ipr. -- -- The IETF invites any interested party to bring to its attention any -- copyrights, patents or patent applications, or other proprietary -- rights that may cover technology that may be required to implement -- this standard. Please address the information to the IETF at ietf- -- ipr@ietf.org. --