-- extracted from rfc1407.txt -- at Mon Nov 15 17:11:56 1999 RFC1407-MIB DEFINITIONS ::= BEGIN IMPORTS Gauge FROM RFC1155-SMI DisplayString, transmission FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; -- This MIB module uses the extended OBJECT-TYPE macro -- as defined in RFC 1212. ds3 OBJECT IDENTIFIER ::= { transmission 30 } -- The DS3/E3 Near End Group -- Implementation of this group is mandatory for all -- systems that attach to a DS3/E3 Interface. -- The DS3/E3 Near End Group consists of four tables: -- DS3/E3 Configuration -- DS3/E3 Current -- DS3/E3 Interval -- DS3/E3 Total -- the DS3/E3 Configuration dsx3ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3/E3 Configuration table." ::= { ds3 5 } dsx3ConfigEntry OBJECT-TYPE SYNTAX Dsx3ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3/E3 Configuration table." INDEX { dsx3LineIndex } ::= { dsx3ConfigTable 1 } Dsx3ConfigEntry ::= SEQUENCE { dsx3LineIndex INTEGER, dsx3IfIndex INTEGER, dsx3TimeElapsed INTEGER, dsx3ValidIntervals INTEGER, dsx3LineType INTEGER, dsx3LineCoding INTEGER, dsx3SendCode INTEGER, dsx3CircuitIdentifier DisplayString, dsx3LoopbackConfig INTEGER, dsx3LineStatus INTEGER, dsx3TransmitClockSource INTEGER } dsx3LineIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object is the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g, network side) with odd numbers." ::= { dsx3ConfigEntry 1 } dsx3IfIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This value for this object is equal to the value of ifIndex from the Interfaces table of MIB II (RFC 1213)." ::= { dsx3ConfigEntry 2 } dsx3TimeElapsed OBJECT-TYPE SYNTAX INTEGER (0..899) ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that have elapsed since the beginning of the near end current error- measurement period." ::= { dsx3ConfigEntry 3 } dsx3ValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION "The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online." ::= { dsx3ConfigEntry 4 } dsx3LineType OBJECT-TYPE SYNTAX INTEGER { dsx3other(1), dsx3M23(2), dsx3SYNTRAN(3), dsx3CbitParity(4), dsx3ClearChannel(5), e3other(6), e3Framed(7), e3Plcp(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The dsx3ClearChannel value means that the C-bits are not used except for sending/receiving AIS. The values, in sequence, describe: TITLE: SPECIFICATION: dsx3M23 ANSI T1.107-1988 dsx3SYNTRAN ANSI T1.107-1988 dsx3CbitParity ANSI T1.107a-1989 dsx3ClearChannel ANSI T1.102-1987 e3Framed CCITT G.751 e3Plcp ETSI T/NA(91)18." ::= { dsx3ConfigEntry 5 } dsx3LineCoding OBJECT-TYPE SYNTAX INTEGER { dsx3Other(1), dsx3B3ZS(2), e3HDB3(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its characteristics. dsx3B3ZS and e3HDB3 refer to the use of specified patterns of normal bits and bipolar violations which are used to replace sequences of zero bits of a specified length." ::= { dsx3ConfigEntry 6 } dsx3SendCode OBJECT-TYPE SYNTAX INTEGER { dsx3SendNoCode(1), dsx3SendLineCode(2), dsx3SendPayloadCode(3), dsx3SendResetCode(4), dsx3SendDS1LoopCode(5), dsx3SendTestPattern(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable indicates what type of code is being sent across the DS3/E3 interface by the device. (These are optional for E3 interfaces.) The values mean: dsx3SendNoCode sending looped or normal data dsx3SendLineCode sending a request for a line loopback dsx3SendPayloadCode sending a request for a payload loopback (i.e., all DS1/E1s in a DS3/E3 frame) dsx3SendResetCode sending a loopback deactivation request dsx3SendDS1LoopCode requesting to loopback a particular DS1/E1 within a DS3/E3 frame dsx3SendTestPattern sending a test pattern." ::= { dsx3ConfigEntry 7 } dsx3CircuitIdentifier OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting." ::= { dsx3ConfigEntry 8 } dsx3LoopbackConfig OBJECT-TYPE SYNTAX INTEGER { dsx3NoLoop(1), dsx3PayloadLoop(2), dsx3LineLoop(3), dsx3OtherLoop(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents the loopback configuration of the DS3/E3 interface. The values mean: dsx3NoLoop Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as it's value. dsx3PayloadLoop The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. dsx3LineLoop The received signal at this interface does not go through the device (minimum penetration) but is looped back out. dsx3OtherLoop Loopbacks that are not defined here." ::= { dsx3ConfigEntry 9 } dsx3LineStatus OBJECT-TYPE SYNTAX INTEGER (1..1023) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the Line Status of the interface. It contains loopback state information and failure state information. The dsx3LineStatus is a bit map represented as a sum, therefore, it can represent multiple failures and a loopback (see dsx3LoopbackConfig object for the type of loopback) simultaneously. The dsx3NoAlarm should be set if and only if no other flag is set. The various bit positions are: 1 dsx3NoAlarm No alarm present 2 dsx3RcvRAIFailure Receiving Yellow/Remote Alarm Indication 4 dsx3XmitRAIAlarm Transmitting Yellow/Remote Alarm Indication 8 dsx3RcvAIS Receiving AIS failure state 16 dsx3XmitAIS Transmitting AIS 32 dsx3LOF Receiving LOF failure state 64 dsx3LOS Receiving LOS failure state 128 dsx3LoopbackState Looping the received signal 256 dsx3RcvTestCode Receiving a Test Pattern 512 dsx3OtherFailure any line status not defined here" ::= { dsx3ConfigEntry 10 } dsx3TransmitClockSource OBJECT-TYPE SYNTAX INTEGER { loopTiming(1), localTiming(2), throughTiming(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The source of Transmit Clock. is derived from the recovered receive clock of another DS3 interface." ::= { dsx3ConfigEntry 11 } -- the DS3/E3 Current -- The DS3/E3 current table contains various statistics being -- collected for the current 15 minute interval. dsx3CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3/E3 Current table." ::= { ds3 6 } dsx3CurrentEntry OBJECT-TYPE SYNTAX Dsx3CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3/E3 Current table." INDEX { dsx3CurrentIndex } ::= { dsx3CurrentTable 1 } Dsx3CurrentEntry ::= SEQUENCE { dsx3CurrentIndex INTEGER, dsx3CurrentPESs Gauge, dsx3CurrentPSESs Gauge, dsx3CurrentSEFSs Gauge, dsx3CurrentUASs Gauge, dsx3CurrentLCVs Gauge, dsx3CurrentPCVs Gauge, dsx3CurrentLESs Gauge, dsx3CurrentCCVs Gauge, dsx3CurrentCESs Gauge, dsx3CurrentCSESs Gauge } dsx3CurrentIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3CurrentEntry 1 } dsx3CurrentPESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of P-bit Errored Seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3CurrentEntry 2 } dsx3CurrentPSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of P-bit Severely Errored Seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3CurrentEntry 3 } dsx3CurrentSEFSs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Severely Errored Framing Seconds, encountered by a DS3/E3 interface in the current 15 minute interval." ::= { dsx3CurrentEntry 4 } dsx3CurrentUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3CurrentEntry 5 } dsx3CurrentLCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Line Coding Violations encountered by a DS3/E3 interface in the current 15 minute interval." ::= { dsx3CurrentEntry 6 } dsx3CurrentPCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of P-bit Coding Violations, encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3CurrentEntry 7 } dsx3CurrentLESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Line Errored Seconds encountered by a DS3/E3 interface in the current 15 minute interval." ::= { dsx3CurrentEntry 8 } dsx3CurrentCCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of C-bit Coding Violations encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3CurrentEntry 9 } dsx3CurrentCESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of C-bit Errored Seconds encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3CurrentEntry 10 } dsx3CurrentCSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of C-bit Severely Errored Seconds encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3CurrentEntry 11 } -- the DS3/E3 Interval -- The DS3/E3 Interval Table contains various statistics -- collected by each DS3/E3 Interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. dsx3IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3/E3 Interval table." ::= { ds3 7 } dsx3IntervalEntry OBJECT-TYPE SYNTAX Dsx3IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3/E3 Interval table." INDEX { dsx3IntervalIndex, dsx3IntervalNumber } ::= { dsx3IntervalTable 1 } Dsx3IntervalEntry ::= SEQUENCE { dsx3IntervalIndex INTEGER, dsx3IntervalNumber INTEGER, dsx3IntervalPESs Gauge, dsx3IntervalPSESs Gauge, dsx3IntervalSEFSs Gauge, dsx3IntervalUASs Gauge, dsx3IntervalLCVs Gauge, dsx3IntervalPCVs Gauge, dsx3IntervalLESs Gauge, dsx3IntervalCCVs Gauge, dsx3IntervalCESs Gauge, dsx3IntervalCSESs Gauge } dsx3IntervalIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3IntervalEntry 1 } dsx3IntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { dsx3IntervalEntry 2 } dsx3IntervalPESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of P-bit Errored Seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3IntervalEntry 3 } dsx3IntervalPSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of P-bit Severely Errored Seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3IntervalEntry 4 } dsx3IntervalSEFSs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Severely Errored Framing Seconds, encountered by a DS3/E3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3IntervalEntry 5 } dsx3IntervalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3IntervalEntry 6 } dsx3IntervalLCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Line Coding Violations encountered by a DS3/E3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3IntervalEntry 7 } dsx3IntervalPCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of P-bit Coding Violations, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3IntervalEntry 8 } dsx3IntervalLESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Line Errored Seconds (BPVs or illegal zero sequences) encountered by a DS3/E3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3IntervalEntry 9 } dsx3IntervalCCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of C-bit Coding Violations encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3IntervalEntry 10 } dsx3IntervalCESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of C-bit Errored Seconds encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3IntervalEntry 11 } dsx3IntervalCSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of C-bit Severely Errored Seconds encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3IntervalEntry 12 } -- the DS3/E3 Total -- The DS3/E3 Total Table contains the cumulative sum of the -- various statistics for the 24 hour period preceding the -- current interval. dsx3TotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3/E3 Total table. 24 hour interval." ::= { ds3 8 } dsx3TotalEntry OBJECT-TYPE SYNTAX Dsx3TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3/E3 Total table." INDEX { dsx3TotalIndex } ::= { dsx3TotalTable 1 } Dsx3TotalEntry ::= SEQUENCE { dsx3TotalIndex INTEGER, dsx3TotalPESs Gauge, dsx3TotalPSESs Gauge, dsx3TotalSEFSs Gauge, dsx3TotalUASs Gauge, dsx3TotalLCVs Gauge, dsx3TotalPCVs Gauge, dsx3TotalLESs Gauge, dsx3TotalCCVs Gauge, dsx3TotalCESs Gauge, dsx3TotalCSESs Gauge } dsx3TotalIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3TotalEntry 1 } dsx3TotalPESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of P-bit Errored Seconds, encountered by a DS3 interface in the previous 24 hour interval" ::= { dsx3TotalEntry 2 } dsx3TotalPSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of P-bit Severely Errored Seconds, encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3TotalEntry 3 } dsx3TotalSEFSs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Severely Errored Framing Seconds, encountered by a DS3/E3 interface in the previous 24 hour interval." ::= { dsx3TotalEntry 4 } dsx3TotalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Unavailable Seconds, encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3TotalEntry 5 } dsx3TotalLCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Line Coding Violations encountered by a DS3/E3 interface in the previous 24 hour interval." ::= { dsx3TotalEntry 6 } dsx3TotalPCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of P-bit Coding Violations, encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3TotalEntry 7 } dsx3TotalLESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Line Errored Seconds (BPVs or illegal zero sequences) encountered by a DS3/E3 interface in the previous 24 hour interval." ::= { dsx3TotalEntry 8 } dsx3TotalCCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of C-bit Coding Violations encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3TotalEntry 9 } dsx3TotalCESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of C-bit Errored Seconds encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3TotalEntry 10 } dsx3TotalCSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of C-bit Severely Errored Seconds encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3TotalEntry 11 } -- The DS3 Far End Group -- Implementation of this group is optional for all systems -- that attach to a DS3 Interface. -- However, only C-bit Parity and SYNTRAN DS3 applications -- have the capability (option) of providing this information. -- The DS3 Far End Group consists of four tables: -- DS3 Far End Configuration -- DS3 Far End Current -- DS3 Far End Interval -- DS3 Far End Total -- The DS3 Far End Configuration Table contains -- configuration information -- reported in the C-bits from the remote end. dsx3FarEndConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Configuration table." ::= { ds3 9 } dsx3FarEndConfigEntry OBJECT-TYPE SYNTAX Dsx3FarEndConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3 Far End Configuration table." INDEX { dsx3FarEndLineIndex } ::= { dsx3FarEndConfigTable 1 } Dsx3FarEndConfigEntry ::= SEQUENCE { dsx3FarEndLineIndex INTEGER, dsx3FarEndEquipCode DisplayString, dsx3FarEndLocationIDCode DisplayString, dsx3FarEndFrameIDCode DisplayString, dsx3FarEndUnitCode DisplayString, dsx3FarEndFacilityIDCode DisplayString } dsx3FarEndLineIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FarEndConfigEntry 1 } dsx3FarEndEquipCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the Far End Equipment Identification code that describes the specific piece of equipment. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 2 } dsx3FarEndLocationIDCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..11)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the Far End Location Identification code that describes the specific location of the equipment. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 3 } dsx3FarEndFrameIDCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the Far End Frame Identification code that identifies where the equipment is located within a building at a given location. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 4 } dsx3FarEndUnitCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..6)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the Far End code that identifies the equipment location within a bay. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 5 } dsx3FarEndFacilityIDCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..38)) ACCESS read-write STATUS mandatory DESCRIPTION "This code identifies a specific Far End DS3 path. It is sent within the Path Identification Message." ::= { dsx3FarEndConfigEntry 6 } -- The DS3 Far End Current -- The DS3 Far End Current table contains various statistics -- being collected for the current 15 minute interval. -- The statistics are collected from the far end block error -- code within the C-bits. dsx3FarEndCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Current table." ::= { ds3 10 } dsx3FarEndCurrentEntry OBJECT-TYPE SYNTAX Dsx3FarEndCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3 Far End Current table." INDEX { dsx3FarEndCurrentIndex } ::= { dsx3FarEndCurrentTable 1 } Dsx3FarEndCurrentEntry ::= SEQUENCE { dsx3FarEndCurrentIndex INTEGER, dsx3FarEndTimeElapsed INTEGER, dsx3FarEndValidIntervals INTEGER, dsx3FarEndCurrentCESs Gauge, dsx3FarEndCurrentCSESs Gauge, dsx3FarEndCurrentCCVs Gauge, dsx3FarEndCurrentUASs Gauge } dsx3FarEndCurrentIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FarEndCurrentEntry 1 } dsx3FarEndTimeElapsed OBJECT-TYPE SYNTAX INTEGER (0..899) ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that have elapsed since the beginning of the far end current error-measurement period." ::= { dsx3FarEndCurrentEntry 2 } dsx3FarEndValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION "The number of previous far end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute far end intervals since the interface has been online." ::= { dsx3FarEndCurrentEntry 3 } dsx3FarEndCurrentCESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far Far End C-bit Errored Seconds encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3FarEndCurrentEntry 4 } dsx3FarEndCurrentCSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Severely Errored Seconds encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3FarEndCurrentEntry 5 } dsx3FarEndCurrentCCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3FarEndCurrentEntry 6 } dsx3FarEndCurrentUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End unavailable seconds encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3FarEndCurrentEntry 7 } -- The DS3 Far End Interval -- The DS3 Far End Interval Table contains various statistics -- collected by each DS3 interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. dsx3FarEndIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Interval table." ::= { ds3 11 } dsx3FarEndIntervalEntry OBJECT-TYPE SYNTAX Dsx3FarEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3 Far End Interval table." INDEX { dsx3FarEndIntervalIndex, dsx3FarEndIntervalNumber } ::= { dsx3FarEndIntervalTable 1 } Dsx3FarEndIntervalEntry ::= SEQUENCE { dsx3FarEndIntervalIndex INTEGER, dsx3FarEndIntervalNumber INTEGER, dsx3FarEndIntervalCESs Gauge, dsx3FarEndIntervalCSESs Gauge, dsx3FarEndIntervalCCVs Gauge, dsx3FarEndIntervalUASs Gauge } dsx3FarEndIntervalIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FarEndIntervalEntry 1 } dsx3FarEndIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { dsx3FarEndIntervalEntry 2 } dsx3FarEndIntervalCESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Errored Seconds encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3FarEndIntervalEntry 3 } dsx3FarEndIntervalCSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Severely Errored Seconds encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3FarEndIntervalEntry 4 } dsx3FarEndIntervalCCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3FarEndIntervalEntry 5 } dsx3FarEndIntervalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End unavailable seconds encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3FarEndIntervalEntry 6 } -- The DS3 Far End Total -- The DS3 Far End Total Table contains the cumulative sum -- of the various statistics for the 24 hour period preceding -- the current interval. dsx3FarEndTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Total table. 24 hour interval." ::= { ds3 12 } dsx3FarEndTotalEntry OBJECT-TYPE SYNTAX Dsx3FarEndTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3 Far End Total table." INDEX { dsx3FarEndTotalIndex } ::= { dsx3FarEndTotalTable 1 } Dsx3FarEndTotalEntry ::= SEQUENCE { dsx3FarEndTotalIndex INTEGER, dsx3FarEndTotalCESs Gauge, dsx3FarEndTotalCSESs Gauge, dsx3FarEndTotalCCVs Gauge, dsx3FarEndTotalUASs Gauge } dsx3FarEndTotalIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FarEndTotalEntry 1 } dsx3FarEndTotalCESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Errored Seconds encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3FarEndTotalEntry 2 } dsx3FarEndTotalCSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Severely Errored Seconds encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3FarEndTotalEntry 3 } dsx3FarEndTotalCCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3FarEndTotalEntry 4 } dsx3FarEndTotalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End unavailable seconds encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3FarEndTotalEntry 5 } -- the DS3/E3 Fractional Group -- Implementation of this group is optional. It is designed -- for those systems dividing a DS3/E3 into channels -- containing different data streams that are of local -- interest. -- The DS3/E3 fractional table identifies which DS3/E3 -- channels associated with a CSU are being used to -- support a logical interface, i.e., an entry in the -- interfaces table from the Internet-standard MIB. -- For example, consider a DS3 device with 4 high speed links -- carrying router traffic, a feed for voice, a feed for -- video, and a synchronous channel for a non-routed -- protocol. -- We might describe the allocation of channels, in the -- dsx3FracTable, as follows: -- dsx3FracIfIndex.2. 1 = 3 dsx3FracIfIndex.2.15 = 4 -- dsx3FracIfIndex.2. 2 = 3 dsx3FracIfIndex.2.16 = 6 -- dsx3FracIfIndex.2. 3 = 3 dsx3FracIfIndex.2.17 = 6 -- dsx3FracIfIndex.2. 4 = 3 dsx3FracIfIndex.2.18 = 6 -- dsx3FracIfIndex.2. 5 = 3 dsx3FracIfIndex.2.19 = 6 -- dsx3FracIfIndex.2. 6 = 3 dsx3FracIfIndex.2.20 = 6 -- dsx3FracIfIndex.2. 7 = 4 dsx3FracIfIndex.2.21 = 6 -- dsx3FracIfIndex.2. 8 = 4 dsx3FracIfIndex.2.22 = 6 -- dsx3FracIfIndex.2. 9 = 4 dsx3FracIfIndex.2.23 = 6 -- dsx3FracIfIndex.2.10 = 4 dsx3FracIfIndex.2.24 = 6 -- dsx3FracIfIndex.2.11 = 4 dsx3FracIfIndex.2.25 = 6 -- dsx3FracIfIndex.2.12 = 5 dsx3FracIfIndex.2.26 = 6 -- dsx3FracIfIndex.2.13 = 5 dsx3FracIfIndex.2.27 = 6 -- dsx3FracIfIndex.2.14 = 5 dsx3FracIfIndex.2.28 = 6 -- For dsx3M23, dsx3SYNTRAN, dsx3CbitParity, and -- dsx3ClearChannel there are 28 legal channels, numbered 1 -- through 28. -- For e3Framed there are 16 legal channels, -- numbered 1 through 16. The channels (1..16) correspond -- directly to the equivalently numbered time-slots. dsx3FracTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FracEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Fractional table." ::= { ds3 13 } dsx3FracEntry OBJECT-TYPE SYNTAX Dsx3FracEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3 Fractional table." INDEX { dsx3FracIndex, dsx3FracNumber } ::= { dsx3FracTable 1 } Dsx3FracEntry ::= SEQUENCE { dsx3FracIndex INTEGER, dsx3FracNumber INTEGER, dsx3FracIfIndex INTEGER } dsx3FracIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FracEntry 1 } dsx3FracNumber OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-only STATUS mandatory DESCRIPTION "The channel number for this entry." ::= { dsx3FracEntry 2 } dsx3FracIfIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) ACCESS read-write STATUS mandatory DESCRIPTION "An index value that uniquely identifies an interface. The interface identified by a particular value of this index is the same interface as identified by the same value an ifIndex object instance. If no interface is currently using a channel, the value should be zero. If a single interface occupies more than one time slot, that ifIndex value will be found in multiple time slots." ::= { dsx3FracEntry 3 } END